Page 3/4
180928
CUSTOMIZATION OPTIONS:
Shut-off Delay
The Shut-off delay is the length of time the light will stay at high-level brightness after motion has ceased to
be detected.This Shut-off delay can be set when operation is in 3, 6 or 0 Mode by using the “TIME” knob
located on the left side of the panel at the back of the sensor lens (See Fig.3) . To increase the shut-off delay,
turn the knob clockwise. To decrease shut off delay, turn the knob counterclockwise. The delay may be
adjusted from a minimum of 5 seconds to a maximum
of 3 minutes. The light will stay on as long as motion is
detected continuously and will automatically turn to low-level brightness when no more motion is detected
after the delay time has passed.
Sensitivity of Motion Sensor
The sensitivity of the motion sensor can be adjusted by using the “Sens” knob located on the right side of the panel at
the back of sensor lens (See Fig.3). To increase sensitivity, turn the knob clockwise. To decrease sensitivity, turn the
knob counterclockwise. The sensitivity may be adjusted from a minimum of 5 feet to a maximum of 40 feet.
Troubleshooting
---The light does not come on at all:
1. Make sure the wall switch and circuit breaker are on.
2. Make sure the wiring is correct.
3. Make sure the bulb is not burned out.
4. Cover the sensor with your palm to verify that the ambient light level is not too high.
----In Test Mode, the light stays on full brightness after 5 seconds:
1. If during daytime, make sure the slide switch is at the TEST position.
2. Whether the motion is detected at all time.
NOTE:
1. The sensitivity of the motion sensor will increase as the
environmental temperature gets cooler. For best performance,
gently clean the lens with a soft cloth every 1 or 2 months to
assure maximum sensitivity.
2. For best performance, install fixture at least 6 feet above
the ground. At such a height, the fixture will provide a
detection distance of up to 40 feet at 77 degrees
Fahrenheit. (See Fig.4)
3.The sensor detects across a detection range of 180 degrees.
(See Fig.5
)
4. The sensor will be more sensitive to motion across its
detection path than motion directly towards it. (See Fig.6)
Fig. 3
Fig. 4
5. To reduce possible nuisances, do not mount the fixture
near a heat source like an air conditioner, vent or furnace
exhaust, or in a direction facing any reflecting object or
other light source.
Fig. 5
AUTO Mode
Manual
Override
Mode
Manual Override Operation Diagram
Turn wall switch OFF-ON
in 3 Seconds
Turn wall switch OFF-ON
in 3 Seconds again
Fig. 2
Fig. 3
5`
6`
10`
40`
Where you install your lantern is important:
Be sure the light is mounted straight on the wall;
otherwise, the detection distance may be limited.
180˚
Motion
Least sensitive
Motion
Most sensitive
Sensor
Fig. 4
Fig. 5
Fig. 6
On the back of the sensor
Time
Low Level Sens
Test 3H 6H 0
5. Manual Override MODE (nighttime operation only; on at dusk,off at dawn)
● In 3, 6 or 0 mode, to shift to manual override mode, turn off the wall switch in 3 seconds and then turn it on again,
the light will turn to high-level brightness at dusk, and turn off automatically at dawn. To return to the previous
settings, turn off the wall switch in 3 seconds and then turn it on again. (See Fig.2 Fig.3)
● The lights will turn off automatically at dawn.