![Vax VCW-05 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/vax/vcw-05/vcw-05_user-manual_3658899008.webp)
Usage
vaxcommercial.co.uk
8
Troubleshooting
To reduce risk of personal injury, unplug spray extractor before servicing.
!
!
!
!
PROBLEM: No water comes out of the nozzle
Cause
: The cleaning product tank is empty.
Solution
: Pour at least 3 litres of water into the tank
and try again.
Cause
: The nozzle is blocked.
Solution
: Clean or change the nozzle.
Cause
: The suction filter in the tank is blocked.
Solution
: Clean the filter.
Cause
: The spraying pump does not work.
Solution
: The spray pump will need to be changed.
Call our service centre for more information.
Cause
: Quick connector is not working properly.
Solution
: Check and clean it.
Cause
: The water duct is soiled with chemical agents.
Solution
: Rinse the pump system with running water.
Cause
: The pump is air locked.
Solution
: Clean the ducts and hoses and vent
the pump.
PROBLEM: The pump is noisy
Cause
: The pump is air locked.
Solution
: Clean the ducts and hoses and vent the
pump. Disconnect the quick-connector in order for
the air to get out.