Vax V-049 Скачать руководство пользователя страница 3

3

Vax Careline 

0870 606 1248

safety information

2. Safety Information

FOR HOUSEHOLD USE ONLY. 

When using the vacuum cleaner, basic safety precautions
should always be observed, including the following:
1.

Only use the vacuum cleaner indoors on dry surfaces.

2.

Turn off the vacuum cleaner controls before
connecting to or disconnecting from the mains
supply.

3.

Always unplug the vacuum cleaner before connecting or
disconnecting the vacuum hose.

4. 

Close attention is necessary when used by or near
children. Do not allow children to use as a toy. 

5. 

Use only as described in this manual. Use only the
manufacturer’s recommended attachments.

6. 

Do not use the vacuum cleaner with a damaged cord
or plug. Do not use the vacuum cleaner if it has been
dropped, damaged, left outdoors or dropped into
water. Return the vacuum cleaner to a Vax
Authorised Service Agent or suitably qualified person
for examination, repair or adjustment.

Call 0870 6061248 for your nearest service centre.

7. 

Do not pull or carry by the cord. Do not use the cord
as a handle, close a door on the cord or pull the cord
around sharp edges or corners. Do not run the
vacuum cleaner over the cord. Keep the cord away
from heated surfaces.

8. 

Do not handle the plug or vacuum cleaner with wet
hands. Do not use outdoors or on wet surfaces.

9. 

Do not put any objects into openings. Do not use
with any openings blocked and do not restrict air
flow. Keep all openings free of dust, lint, hair or
anything that may reduce airflow.

10. Keep hair, loose clothing, fingers and all parts of the

body away from openings and moving parts.

11.  Do not pick up hot coals, cigarette butts, matches or

any hot, smoking or burning objects.

12. Do not pick up flammable or combustible materials

(lighter fluid, petrol, kerosene, etc) or use in the
presence of explosive liquids or vapours.

13.  Do not vacuum up harmful or toxic material 

(chlorine bleach, ammonia, drain cleaner, etc).

14.  Do not vacuum up hard or sharp objects such as glass,

nails, screws, coins, etc.

15.  Do not use without the filters in place.

16.  Use extra care when vacuuming on stairs.

17.  Keep vacuuming area well lit.

18.  Store the vacuum cleaner indoors in a cool, dry area.

19.  Turn off the switch before unplugging.

20. Use only CE-approved 13 amp extension cords. Non-

approved extension cords may overheat. Care should
be taken to arrange the cord so that the cord cannot
be pulled or tripped over.

WARNING: 

Always switch off and unplug the

vacuum cleaner from the electrical outlet before

assembling, opening or emptying the dirt container, or
before connecting/disconnecting the attachments.

CAUTION:

The vacuum cleaner is a very powerful

unit. Before plugging the cord into the outlet make

sure the switch is in the ‘off’ position. Hold the vacuum
cleaner firmly when starting and in use.

IMPORTANT:

If the inlet or hose is blocked, switch

off the vacuum cleaner and remove the blockage(s)

before re-starting the vacuum cleaner.

IMPORTANT:

Cleaning filters improves vacuum

performance. Make sure all filters are replaced back

into the vacuum cleaner before using. Vax recommends
cleaning the pre-motor filter every month and the exhaust
filter every 9-12 months. 

This vacuum cleaner is intended for household use only
and not for commercial or industrial use.

PLEASE KEEP THESE INSTRUCTIONS
FOR FURTHER USE.

!

!

!

!

Vax V-049 User Guide.qxd  28/11/06  15:04  Page 3

Содержание V-049

Страница 1: ...ly before using this cleaner Always fully extend the mains cable before use Retain for future reference Vax careline 0870 6061248 instruction manual Bagless upright Vax model number V 049 Vax V 049 User Guide qxd 28 11 06 15 04 Page 1 ...

Страница 2: ... handle release button 4 On off button 5 Upper cord wrap with quick release 6 Power cord 7 Lower hose inspection tube 8 Telescopic handle 9 Dirt container release 10 Dirt container lid 11 Dirt container 12 Dirt quick release button 13 Air director 14 Wheels 11 10 13 14 Vax V 049 User Guide qxd 28 11 06 15 04 Page 2 ...

Страница 3: ...ving parts 11 Do not pick up hot coals cigarette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objects such as glass nails screws ...

Страница 4: ...pic handle release button on the top of the cleaner and pull handle up until it locks into place Fig 3 3 4 How to Operate Turn the quick cord release for easy cord removal Secure cord in cord clip to keep out of the way while vacuuming see Fig 4 1 Plug cord into electrical outlet Turn cleaner on by pressing the on off switch located on the top of the unit Fig 4 2 To release the handle pull back ha...

Страница 5: ...r Filter Removal and Replacement WARNING To reduce the risk of injury from moving parts unplug before servicing Press button on top of dirt container lid to remove dirt container Fig 5 1 Hold dirt container over a bin and press the quick release button on the side of the container to empty Fig 5 2 To clean the air director first reach in the dirt container turn the director clockwise and pull out ...

Страница 6: ...filter is found inside the lid Twist the filter anticlockwise and pull out to remove Fig 5 6 Tap filter on inside in bin to remove excess dust Fig 5 7 To clean wash under running cold water Fig 5 8 Allow 24 hours to dry before replacing in the cleaner Insert filter back into lid and turn clockwise to lock into place Re attach lid by placing onto dirt container and turning clockwise until it clicks...

Страница 7: ...uuming head guard off NOTE The guard can only be removed attached when the cleaner is in upright position but once it has been removed the cleaner can be laid flat for ease Lift and remove brushbar Fig 6 2 Slide belt off motor shaft and dispose Slide new belt onto motor shaft Fig 6 3 Place new belt in area of brushbar without bristles Fig 6 4 Slide brushbar back into the slots and re attach vacuum...

Страница 8: ...leaner won t pick up loss of suction Cause Dirt container not installed correctly Solution Review dirt container removal and replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Brushbar worn Solution Replace brushbar Cause Broken or worn belt Solution Replace belt Cause Clogged filter Solution Remove filter and clean Cause Vacuuming head brushbar blocked Solution C...

Страница 9: ...of the carpet cleaner before calling There are over 400 approved Vax Service Agents in the UK For the nearest Service Agent please call the Vax Careline www vax co uk 10 Technical Specification Voltage 220 240V 50Hz Wattage 1300W Capacity 1 6l Filters Foam pre motor and pleated paper HEPA central filters Cord length 7 3m Weight 5 2kg Subject to technical change without notice 9 Vax Careline 0870 6...

Страница 10: ...www vax co uk 10 This page has been left intentionally blank Vax V 049 User Guide qxd 28 11 06 15 05 Page 10 ...

Страница 11: ...11 Vax Careline 0870 606 1248 This page has been left intentionally blank Vax V 049 User Guide qxd 28 11 06 15 05 Page 11 ...

Страница 12: ...C Low Voltage Directive EMC 89 336 EEC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website www vax co uk Vax V 049 User Guide qxd 28 ...

Отзывы: