background image

         5

operation

4. How to Operate

Turn the vacuum cleaner on by pressing the on/off
switch located on the lower right side of the cleaner

(Fig.4/1). 
The cleaner can be turned off by pressing the on/off
switch again.

Adjusting the Angle of the Main Body

To adjust the angle of the vacuum cleaner body, push the
release pedal on the lower left side of the cleaner
(Fig.4/2).

Move the handle to the desired position. (A) for
upright position, (B) for normal operation and (C) to clean
under furniture (Fig.4/2).

Height Adjuster

The front of the vacuum cleaner has a height adjuster
that raises and lowers the brushbar to suit the floor type.
With the cleaner NOT connected to the electrical outlet,
and when the vacuum is in the upright position, set the
adjustment to the lowest setting for maximum cleaning.
If the cleaner is difficult to move, push the knob to the
next highest setting until the vacuum is comfortable to
push. The brushbar must reach the carpet for effective
cleaning. (Fig.4/3).

IMPORTANT

: When the vacuum cleaner is stood in

the upright position or when using the hose and

tools, the height adjuster must be set to the highest
position.

WARNING:

To avoid injury, keep loose clothing,

hair, fingers and all other parts of the body away

from any moving part (such as the brushbar). Turn off the
switch and unplug the cleaner before adjusting the
height adjuster.

On/ off
switch

  

Fig.4/1

Fig.4/2

Fig.4/3

!

!

A

B

C

 

  

WARNING: 

This cleaner has a constantly

rotating brushbar which, when left in contact

with lino, parquet and other hard flooring could
potentially cause some damage to the floor surface.

NOTE: 

Vax recommends that you raise the height of

the brushbar when using this cleaner on lino and hard
flooring. Vax cannot be held responsible for damage
to these surfaces if the customer fails to take notice
of this recommendation.

!

press
here

Vax Careline: (UK) 0844 412 8455 (ROI) 1-800 928 308

U89 U90 & U91-P2 Power 2 Series User Guide V2.0:U90-P2 User Guide  13/08/2010  11:44  Page 5

Содержание U91-P2 Series

Страница 1: ...en left in contact with lino parquet and other hard flooring could potentially cause some damage to the floor surface NOTE Vax recommends that you raise the height of the brushbar when using this clea...

Страница 2: ...s 22 TurboTool Some models only 1 2 14 15 16 10 5 12 13 22 22 17 6 9 3 4 7 8 20 21 WARNING This cleaner has a constantly rotating brushbar which when left in contact with lino parquet and other hard f...

Страница 3: ...hot coals cigarette butts matches or any hot smoking or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liqu...

Страница 4: ...the top in place there will be an audible click when it is secure Fig 3 3 Assembly of the Hose Align the tabs on the lower hose inspection tube with the slots on the hose Push and turn the hose clock...

Страница 5: ...uum is comfortable to push The brushbar must reach the carpet for effective cleaning Fig 4 3 IMPORTANT When the vacuum cleaner is stood in the upright position or when using the hose and tools the hei...

Страница 6: ...move the dirt container press the dirt container release button and lift away from the vacuum cleaner Fig 6 1 Cleaning the HEPA Filter Remove the dirt container lid by grasping the dirt container and...

Страница 7: ...is fully dry before putting back on the vacuum cleaner Do not wash in dishwasher 7 Maintenance Cleaning and Changing the Belt TOOLS REQUIRED Crosshead screwdriver WARNING To reduce the risk of electr...

Страница 8: ...e parts by screwing in one 1 screw underneath the small wheel flap and the five 5 screws on the underside of the vacuum cleaner 8 Clearing Blockages WARNING To reduce the risk of electric shock the po...

Страница 9: ...view dirt container replacement Cause Dirt container full or blocked Solution Empty dirt container Cause Clogged filters Solution Remove clean and replace filters PROBLEM Accessories won t pick up Cau...

Страница 10: ...uk 11 Consumables To purchase spares and accessories please visit vax co uk Filter kit 1 1 126184 00 Belt kit 1 1 130669 00 12 Technical Specification Voltage 220 240V 50Hz Wattage 1800W 2000W depend...

Страница 11: ...11 This page has been left intentionally blank Vax Careline UK 0844 412 8455 ROI 1 800 928 308 U89 U90 U91 P2 Power 2 Series User Guide V2 0 U90 P2 User Guide 13 08 2010 11 44 Page 11...

Страница 12: ...Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local A...

Отзывы: