8

operation

Settings

For maximum
cleaning
performance, the
following carpet
height settings are
recommended
(Fig.4/9):

NOTE: If the cleaner is difficult to push, turn knob to
the next higher setting.

• Higher settings: for very deep pile carpet, where easier
pushing effort is desired, while maintaining good cleaning
performance.

Brushbar Shut-off

The brushbar shuts off automatically for tool use, when
the cleaner is in the upright position.

WARNING:

The brush bar must NOT be rotating

when cleaning hard floors. Switch the brush bar

off to prevent damage to lino, parquet and other hard
flooring.

To manually shut off the brushbar for cleaning hard
floors, step on the pedal (A). The indicator (B) will show
red in the “brushbar off” window (Fig.4/10).

To turn the brushbar on, step on the pedal again. The
indicator will show red in the “brushbar on” window.

Cleaning Lightweight Flexible Rugs

Stand on one end of rug and move cleaner toward other
end or edge. Before reaching edge, push down on handle.
This will lift up the nozzle (front of cleaner) as shown and
will prevent rug from clinging to cleaner (Fig.4/11).

Continue to lift up nozzle so that when you have reached
the edge, it is completely off the rug. Move cleaner back
to start again, lower nozzle, and use only forward strokes.

Cleaning Tools

Tools allow for cleaning surfaces above the floor and for
reaching hard to clean areas.

The cleaner is ready for tool use when handle is in
upright position.

CAUTION: The brushbar will not rotate when
the cleaner is in the upright position or the if

the brushbar shut off indicator is in the OFF position
when the handle is lowered.

How to Clean Tools

To clean the hose and TurboTool, wipe off dirt with a
cloth dampened in a mild detergent. Rinse with a damp
cloth.

DO NOT submerge TurboTool in water.

Cleaning tools may be washed in warm water with a
detergent. Rinse and air dry before using.

Removing Hose

When using cleaning tools, place cleaner handle in the
upright position. The brushbar will not rotate when the
cleaner is in the upright position.

Also, turn cleaner OFF before disconnecting and
connecting hose to hose tube (A).

To use hose, lift hose end (B) as shown (Fig.4/12).

When you are finished cleaning with the tools, reposition
hose end into tube.

Fig.4/9

Fig.4/11

Fig.4/10

Fig.4/12

A

A

B

B

!

!

vax.co.uk

U90-M5 & U90-M6 Series User Guide.qxd:VZL-6015 & 6016  9/9/09  16:45  Page 8

Содержание U90-M5 Series

Страница 1: ...Vax careline 0844 412 8455 Bagless upright 5 1 8 7 9 11 10 15 14 12 13 17 18 19 20 21 25 22 23 24 21 16 6 4 3 2 26 27 Vax model number U90 M5 Series U90 M6 Series PLEASE NOTE some parts may vary accor...

Страница 2: ...5 details Vax will not be held responsible for damage to hard floors including lino if the customer fails to switch the brush bar off on these surfaces 12 Furniture guard The guard helps prevent clea...

Страница 3: ...ing or burning objects 12 Do not pick up flammable or combustible materials lighter fluid petrol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxi...

Страница 4: ...sten 3 screws located at the bottom of the upper housing Fig 3 4 Place bottom of dirt container into cleaner body first Pivot container into cleaner body Fig 3 5 Press on dirt container release button...

Страница 5: ...R A SNAP OR A CLICK Fig 3 10 After ends are connected pull on plug to make sure it is securely attached NOTE The plug will only fit together one way If plug is not fitting together check alignment of...

Страница 6: ...n cleaner OFF push switch again Fig 4 1 The cleaner is shipped with the brushbar in the OFF position To turn the brushbar ON step on the pedal A The indicator B will show red in the Brushbar on window...

Страница 7: ...wheels and push forward Fig 4 5 Carrying Cleaner The cleaner can also be moved by using the carrying handle Fig 4 6 Handle Positions The handle of your cleaner has three positions upright for storage...

Страница 8: ...eaner Fig 4 11 Continue to lift up nozzle so that when you have reached the edge it is completely off the rug Move cleaner back to start again lower nozzle and use only forward strokes Cleaning Tools...

Страница 9: ...ush some models only use on hard surface floors Attach extension tube and tools Attach tool or extension tube to the hose Attach tool to extension tube by pushing it firmly onto the tube Twist tube or...

Страница 10: ...irt cup or filters in place Press dirt cup release button A and pivot cup out Fig 5 2 Holding dirt cup over trash receptacle press dirt cup door release button A to open dirt cup door Fig 5 3 Close do...

Страница 11: ...ilter Rinse filter frame cartridge and foam filter under cold water Allow both filter frame and filter to air dry for 24 hours before replacing filter into filter frame Reposition filter frame cartrid...

Страница 12: ...elt is described under Brushbar IMPORTANT Disconnect cleaner from electrical outlet Brushbar can start suddenly Unplug cleaner before turning it over To check the flat belt remove bottom plate as show...

Страница 13: ...up brushbar and slide V belt A off brushbar Fig 6 9 Inspecting the V belt The V belt is designed to last for a long time and is not normally replaced However if the V belt is cracked gouged or broken...

Страница 14: ...bottom plate A Fig 6 13 Unscrew the two Phillips screws and remove belt guard Fig 6 14 Remove brushbar including end plates A and discard Inspect belt to ensure that it is in good condition If belt i...

Страница 15: ...op of the nozzle or by removing the bottom plate and belt guard Fig 6 19 Remove tool from hose Remove bottom plate belt guard and brushbar as described previously Grasp turbine A and pull firmly to re...

Страница 16: ...be on Back of Cleaner Turn cleaner OFF and unplug If blockage can be seen in tube A remove 5 screws using a Phillips screwdriver Pull tube from cleaner remove blockage Fig 7 2 Reposition tube on back...

Страница 17: ...ht setting Solution Move carpet height adjuster to higher setting PROBLEM Smoky burning smell detected Cause Belt broken or stretched Solution Replace brushbar as described in Section 6 PROBLEM Powere...

Страница 18: ...ilters Washable pre motor filter assembly HEPA post motor assembly Washable anti bacterial post motor filter assembly Some models only Cord Length 8 3m approx Weight 10 68kg approx Subject to technica...

Страница 19: ...19 This page has been left intentionally blank Vax Careline 0844 412 8455 U90 M5 U90 M6 Series User Guide qxd VZL 6015 6016 9 9 09 16 45 Page 19...

Страница 20: ...95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Chec...

Отзывы: