Vax C88-CX series Скачать руководство пользователя страница 4

 

FOR HOUSEHOLD USE ONLY. 

When using the vacuum cleaner, basic safety precautions should always

be observed, including the following:

1.

Only use the vacuum cleaner indoors on dry surfaces. 

Do not handle the plug or vacuum cleaner with wet 

hands. Do not use outdoors or on wet surfaces.

2.

Turn off the vacuum cleaner controls before disconnecting or

connecting from the mains supply.

3. 

Always unplug the vacuum cleaner before connecting or

disconnecting the vacuum hose and accessories.

4.

Children should be supervised to ensure that they do not play with

the appliance.

5.

This appliance is not intended for use by persons

(including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge,

unless they have been given supervision or instruction

concerning use of the appliance by a person responsible for

their safety.

6.

Use only as described in this manual. Use only Vax

recommended attachments.

7.

Do not use the vacuum cleaner if it has been dropped,

damaged, left outdoors or dropped into water. Do not use the

vacuum cleaner with a damaged cord or plug. If the supply cord

is damaged, it must be replaced by the manufacturer or a

recommended Service Agent to avoid hazard and invalidating

the guarantee.

8.

Do not pull or carry by cord. Do not use the cord as a handle,

close a door on the cord or pull cord around sharp edges or

corners. Do not run the vacuum cleaner over the cord.Keep the

cord away from heated surfaces.

9.

Do not put any objects into openings. Do not use with any

openings blocked and do not restrict air- flow. Keep all

openings free of dust, lint, hair or anything that might reduce

airflow.

10.

Keep hair, loose clothing, fingers and all parts of the body away

from openings and moving parts.

11.

Do not pick up hot coals, cigarette butts, matches or any hot,

smoking or burning objects.

12.

Do not pick up flammable or combustible materials (lighter 

fluid, petrol, kerosene etc.) or use in the presence of explosive

liquids or vapours.

13.

Do not vacuum up harmful or toxic material (chlorine, bleach,

ammonia, drain cleaner etc.).

14.

Do not vacuum up hard or sharp objects such as glass, nails,

screws, coins, etc.

15.

Do not use without ALL of the filters in place.

16.

Take extra care when vacuuming on stairs.

17.

Keep vacuuming area well lit.  

18.

Store the vacuum cleaner in a cool, dry area.

19.

Turn off the on/off switch before unplugging the 

vacuum cleaner

20.

Use only CE-approved 13 amp extension cords. Non-approved

cords may overheat. Care should be taken to arrange the cord

so that the cord cannot be tripped over.

WARNING: 

Always switch off and unplug the vacuum 

cleaner from the electrical socket before assembling, opening

or emptying the dirt container, or before connecting/disconnecting 

the attachments.

CAUTION:

The vacuum cleaner is a very powerful unit.

Before plugging the cord into the electrical socket, make sure

the switch is in the ‘off’ position. 

IMPORTANT:

If the inlet, hose or telescopic tube is blocked,

switch off the vacuum cleaner and remove the blockage(s)

before re-starting the vacuum cleaner. See Maintenance:

Clearing blockages.

IMPORTANT: 

Washing filters improves vacuum performance.

Vax recommends that they should be checked and cleaned

periodically (depending on the level of use). Make sure all filters are

completely dry before inserting back into the vacuum cleaner.

IMPORTANT: 

The motor is equipped with a thermal cut-out. 

If for any reason the unit should overheat, the thermostat will

automatically turn the unit off. Should this occur, unplug the

vacuum cleaner from the electrical outlet and turn off the switch.

Remove dirt container and empty. Clean filters. Allow the unit  to cool

for approximately one (1) hour. To re-start, plug into an electrical

outlet and switch back on.

This vacuum cleaner is intended for household use only and NOT

for commercial or industrial use.

PLEASE KEEP INSTRUCTIONS    FOR FURTHER USE.

!

!

!

!

!

General Safety Information 

vax.co.uk

3

C88-CX Series UG_User guide  17/04/2012  16:05  Page 3

All manuals and user guides at all-guides.com

Содержание C88-CX series

Страница 1: ...Road Hampton Lovett Droitwich Worcestershire WR9 OQH UK email info vax co uk website vax co uk C88 CX Series UG_User guide 17 04 2012 16 05 Page 12 All manuals and user guides at all guides com a l l...

Страница 2: ...ber What s your serial number Located on the base of the machine Note these down in case you need them in future Please keep instructions for further use Vax Careline UK 0844 412 8455 ROI 1 800 928 30...

Страница 3: ...ral HEPA filter 1 2 3 4 6 7 8 Filters 17 9 Telescopic extension tube 10 Dusting brush 11 Combination floor tool 12 Hose 13 Handle 14 Hose connector 15 Crevice tool 16 TurboTool some models only 17 Tur...

Страница 4: ...trol kerosene etc or use in the presence of explosive liquids or vapours 13 Do not vacuum up harmful or toxic material chlorine bleach ammonia drain cleaner etc 14 Do not vacuum up hard or sharp objec...

Страница 5: ...performance of your machine Please check and wash filters periodically depending on the level of use For full cleaning instructions see pages 5 and 6 IMPORTANT Do not use the vacuum cleaner without a...

Страница 6: ...OTE For convenience there is a parking slot located at the rear of the vacuum cleaner where the floor tool and tubes can be attached for storage and carrying Cleaning the HEPA central filter 24 Tap C8...

Страница 7: ...Remove accessory from the hose handle tube Carefully remove the blockage and return to the cleaner Maintenance Keep your Vax as good as new Cleaning the post motor filter 24 Tap 40 C max Removing blo...

Страница 8: ...rom the unit by pressing the dirt container release catch and then re attaching it to the unit ensuring it is locked firmly back into place What do I do if the unit an accessory becomes damaged or bro...

Страница 9: ...calling Consumables To purchase spares and accessories please visit vax co uk Filter kit Type 55 1 1 130537 00 Technical Specification Voltage 220 240V 50Hz Wattage 1800 2000 W depending on model Capa...

Страница 10: ...ompliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with househo...

Страница 11: ...Notes 10 Vax Careline UK 0844 412 8455 ROI 1 800 928 308 C88 CX Series UG_User guide 17 04 2012 16 05 Page 10 All manuals and user guides at all guides com a l l g u i d e s c o m...

Страница 12: ...Notes vax co uk 11 C88 CX Series UG_User guide 17 04 2012 16 05 Page 11 All manuals and user guides at all guides com...

Отзывы: