background image

TIP

Brushes on the floor head 

should be visible when using 

on hard floors.

Assembling your upright

Press both buttons at end 

of hose and insert into 

hose entry point.

Unwind the power cord. 

Do not pull further than the 

yellow marker.

Insert hose grip into 

extension tube.

Plug into mains and push 

the on/off button to turn 

your machine on.

Insert the other end of the 

telescopic tube into the 

floor head.

Before you begin cleaning

IMPORTANT: The vacuum cleaner is equipped with a thermal cut-out. If for any reason the vacuum cleaner does 

overheat the thermostat will automatically turn the vacuum cleaner off. If this happens, switch the vacuum cleaner  

off and unplug. Remove and empty the dirt container also check the vacuum cleaner for blockages. Allow the vacuum 

cleaner to cool for approximately 1 hour (if you have cleaned the filters please wait 24 hours for the filters to fully dry 

before putting back into the machine).
For best cleaning results clean the pre-motor filter every time the dirt container is emptied and replace  

the post-motor filter every 12 months.
If the vacuum cleaner is blocked, switch off and unplug before removing the blockage.

Important: The base of the vacuum cleaner should always be positioned flat on the floor when starting and in use. 

WARNING: When unwinding the power cord do not pull further than the yellow marker.

Getting started

Using your machine

PLEASE READ ‘LET’S TALK SAFETY’ AT THE BEGINNING BEFORE USE

WARNING

Always switch off the vacuum 

cleaner before connecting  

or disconnecting the hose 

/attachments, or removing and 

emptying the dirt container.

For use on carpets, click 

rocker switch forward. For 

use on hard floors click rocker 

switch back.

Slide vent cover on hose grip open  

to reduce suction if required.

Lower brushes for hard floors.

Raise brushes for carpets.

Содержание C86-TOe Series

Страница 1: ...vax co uk C86 TOe Series Impact 102 Let s get started ...

Страница 2: ... Don t use the power cord as a handle pull the power cord around corners sharp edges or close a door over the power cord Don t unplug vacuum cleaner by pulling on the power cord 8 Don t lift or carry the vacuum cleaner by the dirt container handle 8 Don t vacuum up any flammable or combustible materials lighter fluid petrol kerosene etc or use the vacuum cleaner in an area with explosive vapours o...

Страница 3: ...o purchase consumables and accessories please visit vax co uk Initial Setup for normal operation 1 Use the base accessories a Shortest hose b Extension tube set to shortest practicable length 2 Clean filters installed 3 Dust receptacle empty 4 All Bleeds must be closed 5 Floor heads tools set to Carpet Mode for carpet cleaning 6 Mechanical Agitation turned ON for carpet cleaning 7 Floor heads tool...

Страница 4: ...r if you have cleaned the filters please wait 24 hours for the filters to fully dry before putting back into the machine For best cleaning results clean the pre motor filter every time the dirt container is emptied and replace the post motor filter every 12 months If the vacuum cleaner is blocked switch off and unplug before removing the blockage Important The base of the vacuum cleaner should alw...

Страница 5: ...d shroud under water Max 40 C Leave to dry for 24 hours or until fully dry before placing back in the machine Carrying your machine IMPORTANT Unplug and switch off vacuum cleaner before performing maintenance or troubleshooting checks IMPORTANT The shroud cannot be removed from the dirt container A B Cleaning the pre motor filter Press dirt container release button and lift to remove Leave to dry ...

Страница 6: ...r filter WARNING IMPORTANT Remove accessory from hose or telescopic extension tube before performing maintenance or trouble shooting checks Removing blockages from the TurboTool Tabs Slide the locking ring to remove Lift and separate the housing Using a pair of scissors remove any threads or hair caught around the brushbar Line up the tabs on front of housing and push together to refit Slide locki...

Страница 7: ... pushed into the electrical socket Check the fuse in the plug if this needs replacing always replace with a 13amp fuse The motor thermostat may have tripped If this has happened unplug the vacuum cleaner Remove and empty the dirt container and check the hose for blockages Clean the filters and allow the vacuum cleaner to cool for approximately 1 hour if you have washed the filters you will need to...

Страница 8: ...We ve taken care of cleaning all of the hard to reach areas such as on top of cupboards and in between blinds to the dust that collates behind and within the radiator TurboTool Type 6 1 1 134419 00 Use the TurboTool for vacuuming your stairs upholstery and car interiors It s great for picking up stubborn pet hair Fur n Fluff Tool 1 1 131392 00 Specifically designed to remove extra stubborn pet hai...

Страница 9: ...s manufactured in compliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice VaxUK 2014 All rights reserved VAX VAX Lozenge are trade marks or reg...