background image

Let’s talk technical

TIP

When changing the belt, this is 

the perfect time to clear any 

debris from your brushbar.

What to do if it goes wrong

Using a crosshead screwdriver, 

remove 3 screws from the side of 

the floor head.

Pull to remove the brush bar 

location plate. Remove and dispose 

of old belt.

Clean any debris from spindle. 

Place new belt onto spindle, lining 

up teeth on belt over and onto cog.

Changing the belt

IMPORTANT:

 

Unplug and switch off vacuum cleaner before maintenance or troubleshooting checks

Pull to remove the end cap  

belt cover

•   The plug may not be fully pushed into the electrical socket.

•   Check the fuse in the plug if this needs replacing, always replace 

with a 13amp fuse.

•   The motor thermostat may have tripped. If this has happened, 

unplug the vacuum cleaner. Remove and empty the dirt container 

and check the hose for blockages. Clean the filters and allow 

the vacuum cleaner to cool for approximately 1 hour (if you have 

washed the filters you will need to wait 24 hours for the filters  

to fully dry before putting them back into the vacuum cleaner).

•   There may be a blockage in the hose. Please remove the hose 

from the vacuum cleaner, check and clear any blockages.

•   Empty the dirt container and clean filters. Go to the ‘Taking care  

of your machine’ pages.

•   The brushbar may not be turning. Go to ‘My brushbar isn’t 

turning?’ below.

•   If the accessory/tool will not pick up, check and clear  

any blockages.

•   If the vacuum cleaner is making a whistling noise, please remove 

the dirt container open the bottom and clean the seals. Replace the 

dirt container and retry.

•   If there is an air sucking noise from the top of the dirt container, 

this would indicate a blockage in the machine. Go to ‘Why does my 

vacuum cleaner have no power?’ above.

•   The brushbar may not be switched on, please check the brushbar 

on/off switch.

•   If the vacuum cleaner is not reclined the brushbar will 

automatically switch off.

•   If the red light is flashing the brushbar may be jammed. Clear any 

blockages for further help go to the ‘Let’s talk technical’ pages.

•   To check the belt, go to ‘Changing the belt’ on the ‘Let’s talk 

technical’ pages.

Solution

Problem

WARNING:

 To reduce the risk of personal injury, unplug the vacuum cleaner before performing 

maintenance/troubleshooting checks.

Why does my vacuum 

cleaner have no power?

Why won’t the vacuum 

cleaner turn on?

My brushbar  

isn’t turning?

My vacuum cleaner  

is making an  

excessive noise?

Содержание Air3 Compact

Страница 1: ...vax co uk U86 ACe Series Air3 Compact Let s get started ...

Страница 2: ...is turned off when using your vacuum on the stairs and take extra care when positioning the vacuum cleaner on your stairs Do s continued 3 Use only CE approved 13amp extension cords non approved extension cords may overheat Care should be taken to arrange the extension cord as it can be a trip hazard 3 Store your vacuum cleaner in a cool dry area If filters have been cleaned as per user guide inst...

Страница 3: ...d at the UK local rate Before you call we ll need you to have the following information to hand Your Machine Your Proof of Purchase or Warranty registration code Alternatively you can write to us at Vax Ltd Kingswood Road Hampton Lovett Droitwich Worcestershire WR9 0QH UK Let us know what you think VaxUK Contents Let s talk safety Getting to know your machine Getting started Using your machine Tak...

Страница 4: ...nsumables and accessories please visit vax co uk Handle Wheels Carry handle Power on off button Inner cyclones Dirt container Post motor filter cover Dirt container release button Brushbar blockage indicator Rotating brushbar Pre motor filter Type 58 1 1 131167 00 HEPA Post motor filter Type 102 1 1 134236 00 Belt Kit Type 26 1 1 134530 00 2 in 1 tool Type 3 1 1 132115 00 Getting to know your mach...

Страница 5: ...witch off and unplug the vacuum cleaner before connecting or disconnecting the hose attachments or removing and emptying the dirt container WARNING Always switch off the brushbar before using any accessories hose telescopic extension tube IMPORTANT The vacuum cleaner is equipped with a thermal cut out If for any reason the vacuum cleaner does overheat the thermostat will automatically turn the vac...

Страница 6: ... of the filters in place IMPORTANT The motor is equipped with a thermal cut out If for any reason the unit should overheat the thermostat will automatically turn the unit off For further help go to the What to do if it goes wrong page Using a crosshead screwdriver remove 3 screws from the side of the floor head Pull to remove the brush bar location plate Remove belt Lift and separate brush bar sid...

Страница 7: ...he hose Please remove the hose from the vacuum cleaner check and clear any blockages Empty the dirt container and clean filters Go to the Taking care of your machine pages The brushbar may not be turning Go to My brushbar isn t turning below If the accessory tool will not pick up check and clear any blockages If the vacuum cleaner is making a whistling noise please remove the dirt container open t...

Страница 8: ... with even better results We ve taken care of cleaning all of the hard to reach areas such as on top of cupboards and in between blinds to the dust that collates behind and within the radiator TurboTool Type 6 1 1 134419 00 A TurboTool for your vacuum cleaner Use the TurboTool for vacuuming your stairs upholstery and car interiors It s great for picking up stubborn pet hair Stretch hose Type 2 1 1...

Страница 9: ...s manufactured in compliance with the following Directives Safety 2006 95 EC Low Voltage Directive EMC 2004 108 EC Electromagnetic Compatibility Directive Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice 2014 All rights reserved VAX VAX Lozenge are trade marks or registere...

Отзывы: