VAUPEL 2000 KD Скачать руководство пользователя страница 6

OPERATING MANUAL 2000 KD                                                                                  V7.4/20-EN 

Page | 6 

Excluded from the warranty:   

 

Wear parts.  

 

Damage caused by improper use.  

 

Damage caused by lack of maintenance. 

 

Damage caused by dirt.  

 

Damage caused by untreated compressed air. 

If warranty claims are made, the spray gun must be in its original condition. 
 

11.

 

 Address 

In case of service your sales representative is at your side or contact the  
following address:

 

 

      

Vaupel GmbH 

 

 

Gerätebau & Drucklufttechnik 

 

 

Am Forsthaus 6 

 

 

35713 Eschenburg-Simmersbach 
Germany 

 

 

Telephone:  +49 (0) 2774 80069-0 

 

 

E-Mail:    [email protected]  

 

 

Internet: 

www.vaupel-gmbh.de

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Notice:

 We reserve the right to make technical changes. Illustrations may differ 

from the original. We assume no liability for printing errors. 

Содержание 2000 KD

Страница 1: ...OPERATING MANUAL 2000 KD V7 4 20 EN Page 1 Spray gun 2000 KD Art no 20201 20202...

Страница 2: ...ys keep this operating manual with the spray gun General notice This spray gun was developed for certain applications We explicitly point out that this spray gun must not be modified and or used in a...

Страница 3: ...air stream is used which accelerates when the air nozzle flows through and thus generates negative pressure in the adjoining riser pipe The spray mass is thereby sucked in and sprayed out via the noz...

Страница 4: ...disposed of in an environmentally friendly manner The disposal of the compressed air device must be carried out according to the valid legal regulations 6 Installation Screw in the supplied steel ris...

Страница 5: ...her the spray material can still be processed wheth er the expiry date has passed or whether the material has dried out Gun sprays messy Possible cause Short nozzle riser pipe or ventilation hole dirt...

Страница 6: ...must be in its original condition 11 Address In case of service your sales representative is at your side or contact the following address Vaupel GmbH Ger tebau Drucklufttechnik Am Forsthaus 6 35713...

Страница 7: ...with the above EC guidelines under the general responsibility of Company Vaupel GmbH Ger tebau Drucklufttechnik Am Forsthaus 6 35713 Eschenburg Simmersbach The technical documentation is complete The...

Страница 8: ...er 5 80158 Valve bolt 6 O ring 1 5 x 0 75 mm 7 Valve seal 8 60 3103 003 Spring for valve 9 60 4100 062 O ring 8 x 1 mm 10 30 1120 002 Locking screw 11 30 1424 009 Air nozzle 2 0 mm 12 30 1410 003 Lock...