background image

                                                      

USER MANUAL

 

Vauconsant SA, all rights reserved A329xx & A320xx -rev0-FR, 10th November 2009                       - 2 - 

 

 
 
Manual to be read and kept 

 
 

Contents 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Introduction ……………………………………………………………………..  3 
 

 

Installation / Controls ………………………………………………………..  4 
 

 

Commissioning / Use …………………………………………………………  6 
 

 

Cleaning / Diagnostic ………………………………………………………..  7 
 

 

Maintenance …………………………………………………………………….  8 
 

 

Electric diagrams ………………………………………………………………  9 
 

 

Spare parts / Technical support …………………………………………  11 
 

 

Warranty …………………………………………………………………………  12 

Содержание VISIO-LINE A32008

Страница 1: ...7 804 042 www vauconsant com V VI IS SI IO O L LI IN NE E H HE EA AT TI IN NG G T TO OP P W WI IT TH H H HE EA AT TI IN NG G D DI IS SP PL LA AY Y O OP PT TI IO ON N A32958 2GN 820 x 700 x 70 mm A32963 3GN 1150 x 700 x 70 mm A32965 4GN 1475 x 700 x 70 mm A32969 5GN 1800 x 700 x 70 mm A32972 6GN 2150 x 700 x 70 mm With heating display option A32008 2GN 820 x 700 x 70 430 mm A32013 3GN 1150 x 700 x ...

Страница 2: ...rved A329xx A320xx rev0 FR 10th November 2009 2 Manual to be read and kept Contents Introduction 3 Installation Controls 4 Commissioning Use 6 Cleaning Diagnostic 7 Maintenance 8 Electric diagrams 9 Spare parts Technical support 11 Warranty 12 ...

Страница 3: ... warm at a temperature above 63 C according to hygiene requirements for 90 minutes using GN1 1 65 mm deep gastronorme trays The temperature of the food provided should be between 70 and 80 These units comply with applicable EC norms and should be installed and used following the instructions in this manual to ensure good performance and to be covered by the warranty ...

Страница 4: ...protected by a differential circuit breaker on the general electricity panel o The cabling of the electricity panel must be located in closed premises o Seal the top with a silicone joint o Installation of a breath shield heating display option 1 Dismantle the upper glass brackets with a six sided spanner Ø 2 5 2 Stick the black non slip adhesive patches in the specified markings on the part of th...

Страница 5: ...The control buttons are placed on a panel to be built in o An energy doser with orange on off light for the toughened glass plate or plates o A switch with orange light for the tops with heating display option Lighting switch option Heating energy doser for toughened glass plates Orange on off light ...

Страница 6: ...the hygiene department To maintain this temperature it is indispensable to heat food to a temperature between 70 and 80 C GN A A gastronorme trays should be 65 mm deep The temperature of the heating tops may be set from 40 to 110 C Heating display option Press the switch position 0 Off position 1 On IMPORTANT WARNING It is imperative not to add containers with a temperature above 160 C to avoid we...

Страница 7: ...rcuit breaker Burnt fuse Check the fuse in the electric cabling Orange light off No heat Defective supply Check the supply cable Defective toughened glass plate Replace the toughened glass plate Orange light on No heat Cable disconnected or cut Check and test electricity input to the toughened glass plates Halogen bulb burnt Replace the bulb with one of equivalent power A halogen lamp does not com...

Страница 8: ...nections are located above the halogen support To access remove the 2 mounting screws linking it to the beam Electric cabling Electric cabling is fixed behind the built in control panel To access this remove the 4 screws holding the panel The installer should check electric connections when commissioning the unit then once a year Any maintenance operation should be done by an electrician Lid Top T...

Страница 9: ... A3297 2 Number of GN2 1 600 W toughened glass plates 1 1 2 2 3 Number of GN1 1 300 W toughened glass plates 0 1 0 1 0 Heating top Total power of the top W 600 900 1 200 1 500 1 800 Unit s total power W 600 900 1 200 1 500 1 800 gG A fuse calibre 4 4 6 8 8 Dd Energy doser Rv Heating toughened glass Q Fuse holder Vv Light indicating toughened glass warming A32958 A32963 A32965 A32969 A32972 ...

Страница 10: ...ed glass plates 0 1 0 1 0 Heating top Total power of the top W 600 900 1 200 1 500 1 800 Number of halogen lamps 200W 2 3 4 5 6 Heating display Total power of the heating display W 400 600 800 1 000 1 200 Unit s total power W 1 000 1 500 2 000 2 500 3 000 gG A fuse calibre 6 8 10 12 16 Dd Energy doser Rv Heating toughened glass Lh Halogen lamp Sh Halogen lighting on off Q Fuse holder Vv Light indi...

Страница 11: ...ss heating plate X X X X X 06 0927 GN1 1 530x325mm 300W toughened glass heating plate X X 07 2210 Black silicone joint to stick the heating plates X X X X X Electric equipment 06 1070 Black PVC button 43 mm X X X X X 06 1505 Energy doser X X X X X 06 1600 Orange light X X X X X Halogen heating lighting 06 0617 Aluminium reflector on halogen lighting X X X X X 06 0622 Halogen lamp 200 W X X X X X 0...

Страница 12: ...r caused by defects or poor maintenance of equipment or damage caused by knocks or improper use Any warranty also excludes incidents caused by fortuitous events or force majeure unidentified causes or causes by the buyer s actions of any form whatsoever improper location faults linked to use operation maintenance not in accordance with this manual unqualified staff etc modification of the equipmen...

Отзывы: