Vauconsant COOLBOX Скачать руководство пользователя страница 6

SPARE PARTS 

 
 

Code 

Item description 

 

 

 

Accessories 

09.3098 

Motorized curtain 

 

 

 

Electric equipment 

06.0038 

Self-evaporating tray heating element 

06.3500 

Ventilator 

12.0270 

Thermostat 

12.0500 

Praising pomp 

 

 

 

Refrigerating equipment 

12.2480 

Evaporator 

12.2806 

Group condensation CAJ 4517 ZH 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание COOLBOX

Страница 1: ...mostat page 4 Spare parts page page 6 Rue Charles Hermite Z I des Sables BP 59 54110 Dombasle sur Meurthe France tel 33 03 83 45 82 82 fax 33 03 83 45 82 93 e mail commercial vcs vauconsant com export vauconsant com COOLBOX Refrigerated cupboard with trolley Notice N CC103 mise à jour le 06 novembre 2006 ...

Страница 2: ...out to supply power The thermostat is adjusted in the factory after testing When the desired temperature is obtained the power unit automatically turns off Press the key of the thermostat to turn off the regulation of the unit Adjusting the thermostat Refer to the manual for details Automatic defrosting This function is programmed in the thermostat Adjusted in the factory the defrosting engages ev...

Страница 3: ...pillary Rt Modular timer Cd Condensor Sn Level probe Dh Drier St Atmosphere temperature probe E Evaporator T Thermostat Kb Self evaporating tray relay Tb Safety thermostat for self evaporating tray Im Engine of ascent and descent of the curtain Tm Transformer P Raising pomp V Ventilator Q Fuse holder Vc Condensor fan ...

Страница 4: ...rd is locked At this point it is only possible the viewing of the set point or the MAX or Min temperature stored and to switch ON and OFF the light the auxilary output and the instrument HOW TO UNLOCK THE KEYBOARD Keep the and the keys pressed together for more than 3 s The POn message will be displayed and the keyboard is unlocked 3 2 Meaning of the LED Each LED function is described in the follo...

Страница 5: ...howed alternating with the room temperature except for the P1 which is flashing To reset the EE alarm and restart the normal functioning press any key the rSt message is displayed for about 3s 4 1 EE alarm The instruments are provided with an internal check for the data integrity Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 4 2 Alarm recovery ...

Страница 6: ...essories 09 3098 Motorized curtain Electric equipment 06 0038 Self evaporating tray heating element 06 3500 Ventilator 12 0270 Thermostat 12 0500 Praising pomp Refrigerating equipment 12 2480 Evaporator 12 2806 Group condensation CAJ 4517 ZH ...

Отзывы: