Vauconsant A62308 Скачать руководство пользователя страница 6

                                                      

USER MANUAL

 

Vauconsant SA, all rights reserved A623xx -rev0-ENG, 14/10/2010                                                   - 6 - 

 
Setting of the water level relay

 

 

The top cursor should be set to the DOWN position, pre-set in the factory. 

 

Setting of water hardness: this setting should be adjusted according to the hardness of the water 
where the bain-marie unit is installed:

 

o

 

Activate the wheel with a screwdriver. 

o

 

Set the cursor to the minimum position, the bain-marie well should be full. Excess water 
should be evacuated by the drainage overflow tube. 

o

 

Turn the wheel slowly towards the maximum position and stop when the relay switches 
from the filling position to the heating position. 

o

 

Test by removing the overflow tube. The well empties when the low level is reached. It 
should then be refilled. 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Controls: 

 

The controls are placed on a removable panel to the right of the unit. 

o

 

A mechanical thermostat with orange on-off light for the bain-marie well. 

o

 

A mechanical thermostat with orange on-off light for the ventilated heat cupboard. 

o

 

A switch with orange light for the heating display option. 

 
 
 
 
 
 
 
 
 
 

Operating mode: 

 

 to place in position 

DOWN 

 

Adjustment of the 

water

 

hardness 

 

Содержание A62308

Страница 1: ...ch business registration n C Nancy B 757 804 042 EU VAT number FR 52 757 804 042 E EX XI IG GE EN NC CE E H HE EA AT T B BA AI IN N M MA AR RI IE E W WI IT TH H H HE EA AT TI IN NG G D DI IS SP PL LA...

Страница 2: ...reserved A623xx rev0 ENG 14 10 2010 2 Manual to be read and kept Contents Introduction 3 Installation Controls 4 Commissioning Use 7 Cleaning Diagnostic 8 Maintenance 9 Electric diagrams 11 Spare par...

Страница 3: ...N1 1 150 mm deep gastronorme trays The temperature of the food provided should be between 70 C and 80 C To ensure the smooth operation of the unit it is necessary to set up each gastronorme tray with...

Страница 4: ...six sided spanner 2 5 2 Stick the black non slip adhesive patches in the specified markings on the part of the bracket in contact with the breath shield 3 Install the glass the non domed end should b...

Страница 5: ...l rights reserved A623xx rev0 ENG 14 10 2010 5 Overhang adjustment The unit s overhangs should be positioned as shown below The unit should be level Assembly dismantling of facing Step 1 Step 2 Mounti...

Страница 6: ...vacuated by the drainage overflow tube o Turn the wheel slowly towards the maximum position and stop when the relay switches from the filling position to the heating position o Test by removing the ov...

Страница 7: ...nimum temperature defined by the hygiene department This temperature is maintained for 120 minutes using GN1 1 gastronorme trays 150 deep To maintain this temperature it is necessary to bring food at...

Страница 8: ...is not filled Defective solenoid valve Check that the solenoid valve works properly Bain marie well The water does not stop running Water level poorly adjusted Re adjust the water level see Installati...

Страница 9: ...removable strip then removing the glasswool Ventilated heat cupboard The heating module is placed on the heat cupboard s ceiling To dismantle it remove the 4 mounting screws fixing it to the ceiling...

Страница 10: ...ve the 2 mounting screws linking it to the beam Electric cabling Electric cabling is fixed behind the built in control panel To access this remove the 4 screws holding the panel The installer should c...

Страница 11: ...USER MANUAL Vauconsant SA all rights reserved A623xx rev0 ENG 14 10 2010 11 Electric diagrams Heating element coupling diagram SINGLE PHASE THREE PHASE...

Страница 12: ...mostat on off Ve Heat cupboard s heating light Q2 Solenoid valve s fuse holder Se Heat cupboard s thermostat on off Vte Heat cupboard s thermostat Re Heat cupboard s heating element Tc Well s thermost...

Страница 13: ...ng light Q2 Solenoid valve s fuse holder Se Heat cupboard s thermostat on off Vte Heat cupboard s thermostat Re Heat cupboard s heating element Tc Well s thermostat Features Unit reference A62313 E623...

Страница 14: ...Q1 Main fuse holder Se Heat cupboard s thermostat on off Vte Heat cupboard s thermostat Q2 Solenoid valve s fuse holder Sh Lighting on off Re Heat cupboard s heating element Tc Well s thermostat Feat...

Страница 15: ...ard s thermostat Q2 Solenoid valve s fuse holder Sh Lighting on off Re Heat cupboard s heating element Tc Well s thermostat Features Unit reference A62313 E62313TI A62315 E62315TI A62319 A62322 Number...

Страница 16: ...ell s thermostat 02 0016 Simple 40x49 plughole with 55 mm overflow tube X X X X X 02 0080 PVC flexible hose with bolt for drainage X X X X X 02 0186 Water level electrode with PVC support X X X X X 02...

Страница 17: ...electrical equipment The warranty does not extend to wear caused by defects or poor maintenance of equipment or damage caused by knocks or improper use Any warranty also excludes incidents caused by...