![VAT 612 Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/vat/612-series/612-series_installation-operating-and-maintenance-instructions_4062064046.webp)
Installation, Operating & Maintenance Instructions
Series 612 DN 25 (I.D. 1”), Logic
VAT Vakuumventile AG, CH-9469 Haag, Switzerland
Tel +41 81 771 61 61 Fax +41 81 771 48 30 [email protected] www.vatvalve.com
289700EB
2011-10-21
46/57
Description
Required tool
11. Lubricate seal contact surface of
shaft with a slight film of vacuum
grease (0.0125 ml).
12. Slide both o-rings onto shaft till the
end.
13. Deposit 0.0375 ml vacuum grease
between the o-rings
14. Clean shaft from vacuum grease.
Mount
mechani
cal
uni
t to val
v
e
bod
y
15. Assemble mechanical unit in reverse
order as disassembled (steps 6 to
5).
16. Align pedestal parallel to valve body
and tighten the 2 mounting screws
with 2 Nm.
Allen Wrench
3mm
17. Center plate.
Feeler gauge
0.04 mm
As
sem
b
le
and
a
d
ju
st
pl
at
e
18. Tighten plate screws with 1.1 Nm.
Allen Wrench
3mm
Adequate
feeler gauge