![VAT 121 series Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/vat/121-series/121-series_installation-operating-and-maintenance-instructions_3718701013.webp)
Series 121
OPERATION
600968EA
Edition 2015-11-16
13/27
5.4.1
Manual emergency operation
WARNING
Movable parts
Human body parts may get jammed and severely injured.
Keep human body parts away from movable parts.
Only valid for the ordering number 121..-..34/44 (with solenoid valve)
In case of a power failure, the valve can be actuated manually if compressed air is
available.
Standard solenoid valve
Press push-button (1):
valve opens
Release push-button (1): valve closes
Solenoid valve with lockable emergency operation (option)
Push and rotate in lockable:
valve opens
Push and rotate unlockable:
valve closes