TROUBLE SHOOTING
Series 091
14/27
Edition 19.05.2021
1088779EA
6
Trouble shooting
Failure
Check
Action
See
Valve does not
close / open
Air pressure
Connect
compressed air
«4.3 Compressed air
connection»
Operating pressure
Adjust operating
pressure
Product data sheet
Voltage at solenoid
valve
Connect voltage
«4.4 Electrical connection»
Leak at gate
Gate seal all right?
Replace gate seal
«7.3 Cleaning of the valve gate
and body»
Gate damaged or
contaminated?
Contact VAT
www.vatvalve.com
Operating pressure
Adjust operating
pressure
Product data sheet
Leak at body
Bonnet seal and
sealing surface all
right?
Clean sealing
surface, if
necessary, replace
bonnet seal
«7.3 Cleaning of the valve gate
and body»
Table 6-1