Varytec Studio Par II CDM 150 Скачать руководство пользователя страница 5

 

5 / 9 

4.  Installing the lamp 

  

Always replace the lamp if it becomes damaged or deformed. Verify that the lamp you use is suitable 

for the electronic power at your facility.  

Caution! Operating lamps above or below their rated voltage reduces lamp life and can cause 

premature lamp failure. 

1.  Disconnect the unit from power before installing the lamp. 

Warning! Let lamp cool before changing.   

 

2.  Loosen the knurled bolt on the back of the lamp housing and pull the housing straight out from 

the back of the fixture. 

3.  Remove the lamp from its box, 

holding it by the base.

 

Note: to avoid premature lamp failure, do not touch the lamp during installation, clean it 

carefully with rubbing alcohol and a clean, lint-free cloth before operation. 

4.  Line up the flat sides of the lamp base with the brackets on either side of the socket. Figure 2 

5.  Push down on the lamp base until the lamp is firmly seated. Make sure that the lamp is fully 

seated, with the bottom of the lamp heat sink flush to the lamp housing casting. 

 

Caution: Improperly installed lamps cause premature lamp failure  and socket 

problems. 

 

6.   To reinstall the lamp housing, center it on the reflector and the bolt hole, then tighten the 

knurled bolt to secure the lamp housing in place. 

 

 

 

 

 

Содержание Studio Par II CDM 150

Страница 1: ...User s manual Studio Par II CDM 150...

Страница 2: ...Safety instructions 3 2 Color frame retaining clip 4 3 Cleaning the reflector 4 4 Installing the lamp 5 5 Lens identification 6 6 Changing CDM PAR lenses 6 6 1 Installing a lens 6 6 2 Removing a lens...

Страница 3: ...d amplifier To avoid placing on un stable location Select a level and stable location to avoid vibration Do not use chemicals or volatile liquids for cleaning Use a clean dry cloth to wipe off the dus...

Страница 4: ...ow cleaners on the reflector Chemicals in these cleaners will ham the reflective coatings Do not use paper towels or harsh materials to wipe the reflectors These materials can scratch the surface of t...

Страница 5: ...the lamp from its box holding it by the base Note to avoid premature lamp failure do not touch the lamp during installation clean it carefully with rubbing alcohol and a clean lint free cloth before...

Страница 6: ...x 34 oblong beam shape 30 x51 oblong beam shape 6 Changing CDM PAR lenses Change lenses if they become cracked or badly scratched Caution Never operate the CDM PAR without a lens in place 6 1 Install...

Страница 7: ...e fixture cool before handling the lens 2 Place the fixture on a flat stable work surface Do not install or remove lenses with the unit hanging 3 Position the lens rotation ring with the spring clip a...

Страница 8: ...ly 230 240V 50Hz Power consumption 150W Dimensions L x W x H 280 x 245 x 405 Weight 9 1kg Fitting lamp CDM T lamps Base G12 Fuse 250V 4A Max ambient temperature working 25 C Max ambient temperature ho...

Страница 9: ...9 9 Importeur B K Braun GmbH Industriestra e 1 D 76307 Karlsbad www bkbraun com info bkbraun com...