background image

General information

This user manual contains important information on the safe operation of the device. Read and

follow all safety notes and all instructions. Save this manual for future reference. Make sure

that it is available to all persons using this device. If you sell the device to another user, be sure

that they also receive this manual.
Our products and user manuals are subject to a process of continuous development. We there‐

fore reserve the right to make changes without notice. Please refer to the latest version of the

user manual which is ready for download under 

www.thomann.de

.

General information

 

6

LED Theater Spot 50 3200K, LED Theater Spot 50 3200K WH, LED Theater Spot 50 5600K, LED Theater Spot 50 5600K WH

LED spotlight

Содержание LED Theater Spot 50 3200K

Страница 1: ...LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH LED spotlight User manual...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 12 10 2021 ID 495875 515631 515641 515640...

Страница 3: ...4 Installation 18 5 Starting up 22 6 Connections and controls 25 7 Operating 28 7 1 Starting the device 28 7 2 Main menu 28 7 3 Menu overview 38 7 4 Functions in 1 channel DMX mode 39 7 5 Functions in...

Страница 4: ...tions 41 9 Plug and connection assignments 44 10 Troubleshooting 45 11 Cleaning 47 12 Protecting the environment 48 Table of contents 4 LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theat...

Страница 5: ...LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH 5 LED spotlight...

Страница 6: ...sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve the right to make cha...

Страница 7: ...on to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please cont...

Страница 8: ...by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF Letterings Displays General inf...

Страница 9: ...s Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this ma...

Страница 10: ...ion that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environm...

Страница 11: ...igns Type of danger Warning suspended load Warning danger zone General information LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH 11 LED...

Страница 12: ...damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other person...

Страница 13: ...any covers There are no user serviceable parts inside Do not use the device if covers protectors or optical components are missing or damaged DANGER Electric shock caused by short circuit Always use...

Страница 14: ...e must run outside the barn door and must not interfere with the light emission NOTICE Risk of fire Do not block areas of ventilation Do not install the device near any direct heat source Keep the dev...

Страница 15: ...d other malfunction NOTICE Power supply Before connecting the device ensure that the input voltage AC outlet matches the voltage rating of the device and that the AC outlet is protected by a residual...

Страница 16: ...t 50 5600K WH n Colour rendering index CRI 90 n Max light output 560 Lux 2 m n 15 to 50 manually adjustable beam angle n Operation in Stand alone or DMX mode 1 2 or 3 channels n Master Slave mode n Op...

Страница 17: ...higher operating temperature You can extend the service life of the illuminants by providing adequate ventilation and operating the LEDs with the lowest possible brightness Features LED Theater Spot 5...

Страница 18: ...f injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as...

Страница 19: ...lways be below 40 C 104 F NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximu...

Страница 20: ...in use the device must always be attached to a solid surface or an approved truss Use the openings of the bracket provided for mounting Always work from a stable platform whenever installing moving o...

Страница 21: ...lease note that this device must not be connected to a dimmer Installation LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH 21 LED spotligh...

Страница 22: ...the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards Starting up 22 LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED T...

Страница 23: ...ce to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor 110 W Connections in DMX mode St...

Страница 24: ...start a show immediately Connect the DMX output of the master device to the DMX input of the first slave device Then connect the DMX output of the first slave device to the DMX input of the second sl...

Страница 25: ...Connections and controls PUSH Menu Up Down Enter Connections and controls LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH 25 LED spotligh...

Страница 26: ...cket Power Twist for powering the device 6 Lockable output socket Power Twist for powering another device 7 Locking screw for the mounting bracket 8 Focus control Adjusts the beam angle in a range fro...

Страница 27: ...ecreases the displayed value by one Enter Confirms a selected value Connections and controls LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K...

Страница 28: ...se Up or Down to select the desired parameter or to change the respectively indi cated value 3 When the display shows the desired parameter or value press Enter to enter the respec tive submenu or con...

Страница 29: ...on for 60 seconds the display will automatically turn off Possible changes are not applied Operating LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 5...

Страница 30: ...without changes press Menu without prior confirmation Make sure that this number matches the configuration of your DMX controller The following table shows the respective highest possible DMX address...

Страница 31: ...ut prior confirmation 1 Press Menu to activate the main menu 2 Press Up or Down repeatedly until the display shows Flash and confirm with Enter 3 Then use Up or Down to select a value between 000 and...

Страница 32: ...t one of the three DMX modes 1 Ch 1 channel mode 2 Ch 2 channel mode or 3 Ch 3 channel mode and confirm with Enter 4 To return to the parent menu without changes press Menu without prior confirmation...

Страница 33: ...nd confirm with Enter Display Meaning Display Meaning 1 1 kHz 6 5 kHz 2 2 kHz 7 6 6 kHz 3 2 8 kHz 8 10 kHz 4 3 3 kHz 9 20 kHz 5 4 kHz 4 To return to the parent menu without changes press Menu without...

Страница 34: ...hout changes press Menu without prior confirmation Display Meaning Lin Linear proportional course Log Inverted square curve with a steep course at the begin ning and a flat course at the end logarithm...

Страница 35: ...DMX value 1 the device lights with a brightness 2 between 0 and 100 Linear 0 0 100 255 Exponential 0 0 100 255 S curve 0 0 100 255 Logarithmic 0 0 100 255 Operating LED Theater Spot 50 3200K LED Theat...

Страница 36: ...ith Enter Display Meaning Hold last DMX signal is being held Blck Blackout on DMX failure Man Operating mode Dimmer or Stroboskop on DMX fail 4 To return to the parent menu without changes press Menu...

Страница 37: ...ays the total running time of the LED 4 To return to the parent menu without changes press Menu without prior confirmation Instead of using a DMX controller connect the device to a master device using...

Страница 38: ...sh 000 255 Mode 1 CH 2 CH 3 CH PWM 1 2 3 4 5 6 7 8 9 Curve Lin Log Exp S Cu Fail Hold Blck Man Info Ver Hrs Operating 38 LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600...

Страница 39: ...dimmer 0 to 100 7 5 Functions in 2 channel DMX mode Channel Value Function 1 0 255 Master dimmer 0 to 100 2 0 255 Strobe effect 0 to 100 Operating LED Theater Spot 50 3200K LED Theater Spot 50 3200K W...

Страница 40: ...Value Function 1 0 255 Master dimmer 0 to 100 2 0 255 Fine dimmer 0 to 100 3 0 255 Strobe effect 0 to 100 Operating 40 LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K...

Страница 41: ...15 50 manually adjustable on the device Control DMX buttons and display on the unit Number of DMX channels 1 2 or 3 Input connections Voltage supply lockable input socket Power Twist DMX control XLR...

Страница 42: ...ltage 100 240 V 50 60 Hz Protection class IP20 Mounting options hanging standing Dimensions W H D 135 mm 167 mm 180 mm Weight 2 kg Ambient conditions Temperature range 0 C 40 C relative humidity 20 80...

Страница 43: ...Housing colour Item no 495875 515641 black Item no 515631 515640 white Further information Technical specifications LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED...

Страница 44: ...a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input Please refer to the drawing and table...

Страница 45: ...Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may occur during operation We give you some suggestions for eas...

Страница 46: ...er DMX controller 4 Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or interfer ence to DMX interface circuits If the procedures recommended above do...

Страница 47: ...nd lens cleaner item no 280122 n Always dry the parts carefully The fan grids of the device must be cleaned of any contamination such as dust etc on a reg ular basis Before cleaning switch off the dev...

Страница 48: ...subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household waste Dispose of this device through an approv...

Страница 49: ...Notes LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH 49 LED spotlight...

Страница 50: ...Notes 50 LED Theater Spot 50 3200K LED Theater Spot 50 3200K WH LED Theater Spot 50 5600K LED Theater Spot 50 5600K WH LED spotlight...

Страница 51: ......

Страница 52: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...

Отзывы: