background image

Event Par IP65 4in1 14x8W,

Event Par IP65 4in1 14x8W WDMX

LED PAR

User manual

Содержание Event Par IP65 4in1 14x8W

Страница 1: ...Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR User manual ...

Страница 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Straße 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 25 02 2019 ID 452127_435626 ...

Страница 3: ...Safety 11 3 Features 16 4 Installation 18 5 Starting up 22 6 Connections and controls 26 7 Operating 32 7 1 Starting the device 32 7 2 Main menu 32 7 3 Menu overview 36 7 4 Functions in 4 channel DMX mode 38 7 5 Functions in 7 channel DMX mode 38 Table of contents Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 3 LED PAR ...

Страница 4: ... 7 Remote control 42 8 Technical specifications 45 9 Plug and connection assignments 48 10 Troubleshooting 49 11 Cleaning 51 12 Protecting the environment 52 Table of contents 4 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 5: ...rsons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous development We there fore reserve the right to make changes without notice Please refer to the latest version of the user manual which is ready for download under www thomann de General information Event Par IP65 4in1 14x8W E...

Страница 6: ...unction in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal consultation For personal consultation please contact our technical hotline Service If you have any problems with the device the customer service will gladly assist you General information 6 Event Par IP65 4in1 14x8W Ev...

Страница 7: ...ectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics Examples 24ch OFF Letterings Displays General information Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 7 LED PAR ...

Страница 8: ... 1 Switch on the device 2 Press Auto ð Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of symbols and signal words that are used in this manual Instructions General information 8 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 9: ... indicates a pos sible dangerous situation that can result in death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is not avoided Warning signs Type of danger Warning high voltage Warning hot surface General information Event Par IP65 4in1 14x8W Event Par I...

Страница 10: ...Warning signs Type of danger Warning dangerous optical radiation Warning suspended load Warning danger zone General information 10 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 11: ...liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical sensorial and intellectual abilities and having corresponding knowledge and experience Other persons may use this device only if they are supervised or instructed by a person who is responsible for their safety Extend the life of the device by regular breaks in operati...

Страница 12: ... g knobs or the like from the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by short circuit Do not modify the mains cable or the plug Failure to do so could result in electric shock death or fire If in doubt seek advice from a registered electrician Safety Safety 12 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W...

Страница 13: ... Never remove any covers There are no user serviceable parts inside Do not use the device if covers protectors or optical components are missing or damaged WARNING Eye damage caused by high light intensity Never look directly into the light source Safety Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 13 LED PAR ...

Страница 14: ...ce of the device can become very hot during operation Do not touch the device with bare hands during operation and after switching off wait for at least 15 minutes NOTICE Risk of fire Do not block areas of ventilation Do not install the device near any direct heat source Keep the device away from naked flames Safety 14 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 15: ...et is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and when it is unused for long periods of time to reduce the risk of electric shock or fire Safety Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 15 LED PAR ...

Страница 16: ... in automatic show programmes n Master Slave operation n Protection class IP65 n Sturdy double bracket for secure attachment to trusses or firm footing on the ground n Rugged die cast aluminium housing Varytec Event Par IP65 4in1 14x8W WDMX also n Built in wireless solution receiver module G5 for wireless control n W DMX transmitter optionally available item number 366876 Features 16 Event Par IP6...

Страница 17: ...ipment resistance to changing ambient conditions as well as against the effects of sun light and UV rays The seals and screw connections of the equipment must be checked regularly to ensure a fault free operation In cases of doubt consult a specialist workshop in due time For technological reasons the light output of LEDs decreases over their lifetime This effect increases with higher operating te...

Страница 18: ... the original packaging or your own packaging material suitable for transport or storage respectively WARNING Risk of injury caused by falling objects Make sure that the installation complies with the standards and rules that apply in your country Always secure the device with a secondary safety attachment such as a safety cable or a safety chain Installation 18 Event Par IP65 4in1 14x8W Event Par...

Страница 19: ...ech nical Specifications of the User Manual NOTICE Use of stands When mounting the device onto a stand ensure that the stand is in a safe and stable position and that the weight of the device does not exceed the maximum permissible load capacity of the stand Installation Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 19 LED PAR ...

Страница 20: ...input or output to audio devices such as mixers or ampli fiers NOTICE Possible damage due to moisture Moisture entering into open connectors plugs and couplers of DMX or power cords can cause short circuits Close unused connectors with end caps intended for this purpose www thomann de Installation 20 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 21: ...ngs provided on the two piece bracket for attaching Always work from a stable platform whenever installing moving or servicing the unit In doing so the area underneath the unit must be cordoned off Please note that this device must not be connected to a dimmer Mounting options Installation Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 21 LED PAR ...

Страница 22: ...ons while the device is off Use the shortest possible high quality cables for all connections Take care when running the cables to prevent tripping hazards Starting up 22 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 23: ... output of the first DMX device to the input of the second one and so on to form a daisy chain Always ensure that the output of the last DMX device in the daisy chain is terminated with a resistor 110 Ω W Connections in DMX mode Starting up Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 23 LED PAR ...

Страница 24: ...ction is ideal when you want to start a show immediately Connect the DMX output of the master device to the DMX input of the first slave device Then connect the DMX output of the first slave device to the DMX input of the second slave device and so on Connections in master slave mode Starting up 24 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 25: ...ing base of the remote control Slide the battery holder back into the remote until it clicks into place When shipping the battery is already installed in the remote and protected against discharge by a transparent plastic foil Remove the plastic foil prior to first use Inserting the battery into the remote control Starting up Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 25 LED PAR ...

Страница 26: ...6 Connections and controls Varytec Event Par IP65 4in1 14x8W item number 435626 Connections and controls 26 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 27: ...yed value by one UP Increases the displayed value by one ENTER Opens a submenu or confirms a value 2 Pressure compensation element 3 Locking screws for the brackets 4 DMX IN DMX input designed as 3 pin XLR chassis mounted plug IP65 Connections and controls Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 27 LED PAR ...

Страница 28: ... for hanging or floor setup 7 POWER OUT Lockable output socket Power Twist TR1 IP65 for the power supply of further devices 8 POWER IN Lockable input socket Power Twist TR1 IP65 for powering the device Connections and controls 28 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 29: ...Varytec Event Par IP65 4in1 14x8W WDMX item number 452127 Connections and controls Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 29 LED PAR ...

Страница 30: ...yed value by one UP Increases the displayed value by one ENTER Opens a submenu or confirms a value 2 Pressure compensation element 3 Locking screws for the brackets 4 DMX IN DMX input designed as 3 pin XLR chassis mounted plug IP65 Connections and controls 30 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 31: ...etup 7 POWER OUT Lockable output socket Power Twist TR1 IP65 for the power supply of further devices 8 POWER IN Lockable input socket Power Twist TR1 IP65 for powering the device 9 ANT Antenna for wireless control via W DMX Connections and controls Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 31 LED PAR ...

Страница 32: ...se UP or DOWN to select a submenu or a value When the display shows the desired submenu or value press ENTER to open the submenu or to select the desired value To close the main menu press MENU All previously made settings are retained even when you disconnect the device from the power grid The following table shows the setting options Operating 32 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x...

Страница 33: ...de DMX Display CH4 CH7 CH9 MAnu Adjusts the intensity of the colours red green blue and white Display red Gree bLUe Whte CoLo Defines a default colour Display Co1 CO15 Auto Adjusts an effect Display SH 1 SH 5 Adjusts the effect speed Display SP01 SP05 Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 33 LED PAR ...

Страница 34: ...ivity for sound control Display So00 S010 FLSH Adjusts the strobe speed Display FL01 FL15 SLAU Enables disables the slave mode In slave mode the device auto matically follows the settings of the master device Slave mode enabled SL n Slave mode disabled SL u Operating 34 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 35: ...lable only for Varytec Event Par IP65 4in1 14x8W WDMX WDMX enabled on WDMX disabled oFF Ir Enables or disables the remote control Remote control enabled on Remote control disabled oFF Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 35 LED PAR ...

Страница 36: ...7 3 Menu overview Varytec Event Par IP65 4in1 14x8W item number 435626 Operating 36 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 37: ...Varytec Event Par IP65 4in1 14x8W WDMX item number 452127 Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 37 LED PAR ...

Страница 38: ...reen 0 to 100 3 0 255 Intensity blue 0 to 100 4 0 255 Intensity white 0 to 100 7 5 Functions in 7 channel DMX mode Channel Value Function 1 0 255 Intensity red 0 to 100 2 0 255 Intensity green 0 to 100 3 0 255 Intensity blue 0 to 100 Operating 38 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 39: ...r 0 bis 100 6 0 10 open 11 255 Strobe effect increasing speed 7 0 10 Without function 11 100 Colour change increasing speed 101 200 Colour change with cross fade increasing speed 201 255 Sound control Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 39 LED PAR ...

Страница 40: ...sity blue 0 to 100 4 0 255 Intensity white 0 to 100 5 0 255 Master dimmer 0 bis 100 6 0 10 open 11 255 Strobe effect increasing speed 7 0 10 Without function 11 32 Colour change with 7 colours 33 50 Colour change red orange 51 68 Colour change with 15 colours Operating 40 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 41: ...15 colours 101 200 Colour change with cross fade increasing speed 201 255 Sound control 8 0 255 Colour change or fade programme speed if channel 7 11 200 9 0 14 No function 15 255 Sound control increasing sensitivity Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 41 LED PAR ...

Страница 42: ...7 7 Remote control Operating 42 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 43: ...olour schemes red green red blue red white amber blue 12 BLACKOUT Activates the blackout function and deactivates it again FULLON Activates all colours AUTO Starts stops Automatic mode FADE Activates the fader Operating Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 43 LED PAR ...

Страница 44: ...hing light function strobe effect with the last colour selected 13 Red Green Blue White Amber Purple Activates the colours red green blue white amber purple Operating 44 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 45: ...e control IR remote control Number of DMX channels 4 7 9 Input connections Voltage supply Lockable Power Twist input socket TR1 IP65 DMX control XLR chassis mounted socket IP65 3 pin Output connections Voltage supply Lockable Power Twist output socket TR1 IP65 Technical specifications Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 45 LED PAR ...

Страница 46: ...mote control Battery type Lithium button cell 3 V CR 2025 Degree of protection IP65 Mounting options Hanging standing Dimensions W H D 293 mm 298 mm 155 mm Weight 4 8 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 50 non condensing Technical specifications 46 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 47: ...mixture RGBW RGBW LED type x in 1 x in 1 Base housing Yes Yes Fanless Yes Yes Remote control Included Included Wireless DMX No Yes Housing colour Black Black Further information Technical specifications Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 47 LED PAR ...

Страница 48: ...an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for DMX input Please refer to the drawing and table below for the pin assignment of a suitable XLR plug Pin Configuration 1 Ground shielding 2 Signal inverted DMX cold signal 3 Signal DMX hot signal Introduction DMX connec...

Страница 49: ...se ordi nary microphone cables Never connect the DMX input or output to audio devices such as mixers or ampli fiers In the following we list a few common problems that may occur during operation We give you some suggestions for easy troubleshooting Troubleshooting Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 49 LED PAR ...

Страница 50: ... DMX polarity 3 Try using another DMX controller 4 Check to see if the DMX cables run near or alongside to high voltage cables that may cause damage or interfer ence to DMX interface circuits If the procedures recommended above do not succeed please contact our Service Center You can find the contact information at www thomann de Troubleshooting 50 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x...

Страница 51: ...ng depends on the operating environment wet smoky or particularly dirty surroundings can cause more accumulation of dirt on the optics of the device n Clean with a soft cloth using our lamp and lens cleaner item no 280122 n Always dry the parts carefully Optical lenses Cleaning Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 51 LED PAR ...

Страница 52: ...that they are fed to a recovery Please follow the notes and markings on the packaging Batteries must not be disposed of as domestic waste or thrown into fire Dispose of the bat teries according to national or local regulations regarding hazardous waste To protect the environment dispose of empty batteries at your retail store or at appropriate collection sites Disposal of the packaging mate rial D...

Страница 53: ...waste Dispose this device through an approved waste disposal firm or through your local waste facility When discarding the device comply with the rules and regulations that apply in your country If in doubt consult your local waste disposal facility Disposal of your old device Protecting the environment Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX 53 LED PAR ...

Страница 54: ...Notes 54 Event Par IP65 4in1 14x8W Event Par IP65 4in1 14x8W WDMX LED PAR ...

Страница 55: ......

Страница 56: ...Musikhaus Thomann Hans Thomann Straße 1 96138 Burgebrach Germany www thomann de ...

Отзывы: