PLEASE NOTE – ANY EQUIPMENT OR ASSOCIATED CABLING CONNECTED TO THIS
DEVICE MUST BE NON-INCENDIVE AND/OR SUITABLE FOR THE CLASS I DIVISION 2
AREA IN WHICH IT IS TO BE INSTALLED.Power Connection (Power In)
Power Connection (Power In)
The VESA Mount Enclosed PC includes an AC line cord which is 3ft long with stripped wires at
the connection end. The user must supply a lockable industrial-type power supply plug to mate
with their power outlet.
Also, the end user must either supply a switch to their power outlet
suitable for Class I, Division 2 use (if adjacent to the power outlet), or locate the said switch
outside the hazardous area.
Serial Connections (COM)
The Enclosed VESA PC is supplied with a serial connector configured for RS-232. The
connector is a 9 pin female connectors and can be set up for any baud rate from 300 to 19.2
baud. The connector is located on the bottom panel of the system.
Ethernet Connections (LAN)
The Enclosed PC is supplied with integrated Ethernet. The interface will support 10/100/1000
BaseT connection to a local area network (LAN). The Enclosed PC is supplied with a RJ-45
female connector located on the bottom panel of the system.
USB Connections (USB)
The Enclosed VESA PC is supplied with three USB 2.0 connectors, which are located on the
bottom panel of the system.