Discharge Current
The cell shall be discharged at less or equal than the
maximum discharge current specified in the Data Sheet.
High discharge current may reduce the discharging
capacity significantly, or cause overheating.
Discharge Temperature
The cell shall be discharged within the temperature
range that is specified in the Data Sheet.
Over-Discharging
Not using the cell(s) for a long time may lead to over-
discharge. In order to prevent overdischarging, the
cell(s) shall be charged periodically to maintain a
voltage in the range of 3 V to 3.8 V.
Over-discharging may cause loss of cell performance, or
damage battery function.
The application device shall be equipped with a device
to prevent further discharging below the cutoff voltage
specified in the Data Sheet.
PCM over-discharge detection threshold / voltage must
not be used as cutoff voltage for battery.
Also the charger shall be equipped with a device to
control the recharging procedures as follows:
In case of over-discharging, the cell(s) / battery pack
shall start with a low current (0.01 – 0.07C) for 15 – 30
minutes, i.e. precharging, before rapid charging starts.
The charging according to the Data Sheet shall be
started after the individual cell voltage has risen
above about 3 V within 15 – 30 minutes, which can be
determined and controlled by the use of an appropriate
timer for precharging.
In case the individual cell voltage does not rise to about
3 V within the pre-charging time, the charger shall have
functions to stop the further continuous charging and
display that the cell(s) is / are in an abnormal state.
7.3 Discharging
Prohibition of Trickle Charging or
Continuous Charging
Trickle charging or continuous charging is prohibited.
Trickle charging conditions or continuous charging can
lead to overcharging, generation of internal pressure
and degeneration of the cell.
The cell shall be charged with constant current until
4.3 V ± 50 mV, then with constant voltage and tapering
current. At approx. 0.02C current the charging must be
stopped. Charging should restart only if appreciable
capacity has been discharged from the cell, or the cell
voltage has fallen itself below a voltage level of 4.0 V.
COINPOWER | HANDLING PRECAUTIONS AND PROHIBITIONS
Содержание 63094
Страница 10: ...COINPOWER 10 2 Miscellaneous 2 1 Specification table VARTA CoinPower Batteries 11 2 2 Data Matrix Code 13 ...
Страница 15: ...COINPOWER 15 3 1 Charging 16 3 2 Discharging 18 3 3 Charging IC 19 3 Charging and Discharging ...
Страница 20: ...COINPOWER 20 4 Reliability and life expectancy ...
Страница 22: ...COINPOWER 22 5 Storage ...
Страница 40: ...COINPOWER 40 9 Application check list ...
Страница 42: ...COINPOWER 42 10 Glossary ...