background image

 

POWX1730 

EN

 

Copyright © 2015 VARO 

P a g e

 | 

9

 

www.varo.com 

for condensation water 
(11) leaks. 

seal on the screw and replace if 
necessary. 

The compressor 
starts, pressure is 
shown on the 
pressure gauge, 
but the tools do 
not start. 

1. Loose hose 
connections 

1. Check the compressed air hose and 
tools and replace if necessary. 

2. Leak in a quick-lock 
coupling 

2. Check the quick-lock coupling and 
replace if necessary. 

3. Insufficient pressure 
set on the pressure 
regulator. 

3. Open the pressure regulator further. 

12 WARRANTY 

 

This product is warranted for a 36-month period effective from the date of purchase by the 
first user. 

 

This warranty covers all material or production flaws excluding : batteries, chargers, 
defective parts subject to normal wear & tear such as bearings, brushes, cables, and 
plugs, or accessories such as drills, drill bits, saw blades, etc. ; damage or defects 
resulting from maltreatment, accidents or alterations; nor the cost of transportation. 

 

Damage and/or defects resulting from inappropriate use also do not fall under the 
warranty provisions. 

 

We also disclaim all liability for any bodily injury resulting from inappropriate use of the 
tool. 

 

Repairs may only be carried out by an authorised customer service centre for Powerplus 
tools. 

 

You can always obtain more information at the number 00 32 3 292 92 90. 

 

Any transportation costs shall always be borne by the customer, unless agreed otherwise 
in writing. 

 

At the same time, no claim can be made on the warranty if the damage of the device is the 
result of negligent maintenance or overload. 

 

Definitely excluded from the warranty is damage resulting from fluid permeation, excessive 
dust penetration, intentional damage (on purpose or by gross carelessness), inappropriate 
usage (use for purposes for which the device is not suitable), incompetent usage (e.g. not 
following the instructions given in the manual), inexpert assembly, lightning strike, 
erroneus net voltage. This list is not exhaustive. 

 

Acceptance of claims under warranty can never lead to the prolongation of the warranty 
period nor commencement of a new warranty period in case of a device replacement. 

 

Devices or parts which are replaced under the warranty  therefore remain the property of 
Varo NV. 

 

 We reserve the right to reject a claim whenever the purchase cannot be verified or when it 
is clear that the product has not been properly maintained. (Clean ventilation slots, carbon 
brushes serviced regularly, etc.). 

 

Your purchase receipt must be kept as proof of date of purchase. 

 

Your appliance must be returned undismantled to your dealer in an acceptably clean state, 
(in its original blow-moulded case if applicable to the unit), accompanied by proof of 
purchase. 

13 ENVIRONMENT 

Should  your  appliance  need  replacement  after  extended  use,  do  not  discard  it 
with the household rubbish but dispose of it in an environmentally safe way. 
Waste  produced  by  electrical  machine  items  should  not  be  handled  like  normal 
household rubbish. Please recycle where recycle facilities exist. Check with your 
Local Authority or retailer for recycling advice. 

Содержание POWERPLUS POWX1730

Страница 1: ...lasting guns 5 5 2 Safety information for paint spraying 5 5 3 Operating pressure vessels 6 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR 6 7 ASSEMBLY AND STARTING 6 7 1 Fitting the wheels 3 6 7 2 Fitting the supporting foot 4 6 7 3 Voltage 6 7 4 On Off switch 8 7 7 5 Adjusting the pressure Fig 2 7 7 6 Setting the pressure switch 7 8 CLEANING AND MAINTENANCE 7 8 1 Cleaning 7 8 2 Condensation wat...

Страница 2: ...POWX1730 EN Copyright 2015 VARO P a g e 2 www varo com 13 ENVIRONMENT 9 14 DECLARATION OF CONFORMITY 10 ...

Страница 3: ...packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packing materials are no to...

Страница 4: ...ing pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual curren...

Страница 5: ...hese instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work to be performed Use of the power tool for operations different from intended could lead to a hazardous situation 4 5 Service Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of th...

Страница 6: ...e then please contact the customer service workshop 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR Examine the machine for signs of transit damage Report any damage immediately to the company which delivered the compressor The compressor should be set up near the working consumer Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the ...

Страница 7: ...sure We recommend that you clean the appliance immediately after you use it Clean the appliance regularly with a damp cloth and some soft soap Do not use cleaning agents or solvents these may be aggressive to the plastic parts in the appliance Ensure that no water can get into the interior of the appliance You must disconnect the hose and any spraying tools from the compressor before cleaning Do n...

Страница 8: ... standard K 3 Acoustic pressure level LpA 77 dB A Acoustic power level LwA 97 dB A ATTENTION Wear hearing protection when sound pressure is over 85 dB A 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY The compressor does not start 1 No supply voltage 1 Check the supply voltage the power plug and the socket outlet 2 Insufficient supply voltage 2 Make sure that the extension cab...

Страница 9: ...time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the ins...

Страница 10: ...n of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 94dB A 97dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN5501...

Отзывы: