The details and designations of the Ordinance on Hazardous Substances, which are 
displayed on the outer packaging of the processed material, must be observed. Additional 
protective measures are to be undertaken if necessary, particularly the wearing of suitable 
clothing and masks. 

 

The work room has to be bigger than 30 m3 and have sufficient ventilation for spraying 
and drying. Never spray into the wind. It is always imperative to observe the regulations of 
your local police authorities when spraying combustible or hazardous substances. 

 

Never process media such as white petroleum spirit, butyl alcohol and methylene chloride 
with the PVC pressure hose (reduced life span). 

5.3 

Operating pressure vessels 

 

An operator of a pressure vessel is required to keep the pressure vessel in good working 
order, to operate it properly, to supervise its use, to carry out essential maintenance and 
repair work immediately, and to introduce essential safety measures according to 
requirements. 

 

The supervisory authorities may order essential safeguards from case to case. 

 

A pressure vessel may not be operated if it has any defects which constitute a danger to 
employees or third parties. 

 

The pressure vessel must be regularly inspected for damage, e.g. rust. If you discover any 
damage, then please contact the customer service workshop. 

6  POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR 

 

Examine the machine for signs of transit damage. Report any damage immediately to the 
company which delivered the compressor. 

 

The compressor should be set up near the working consumer. 

 

Avoid long air lines and long supply lines (extensions). 

 

Make sure the intake air is dry and dust-free. 

 

Do not set up the compressor in damp or wet rooms. 

 

The compressor may only be used in suitable rooms (with good ventilation and an ambient 
temperature from +5°C to +40°C). There must be no dust, acids, vapors, explosive gases 
or inflammable gases in the room. 

 

The compressor is designed to be used in dry rooms. It is prohibited to use the 
compressor in areas where work is conducted with sprayed water. 

7  ASSEMBLY AND STARTING 

Important! You must fully assemble the appliance before using it for the 
first time. 

7.1 

Fitting the wheels (3) 

Fit the supplied wheels as shown in Fig. 3. 

7.2 

Fitting the supporting foot (4) 

Fit the supplied rubber stopper as shown in Fig. 4. 

7.3 

Voltage 

The compressor is equipped with a mains cable with shock-proof plug. This can be connected 
to any 230V ~ 50Hz shock-proof socket which is protected by a 16 A fuse. Before you use the 
machine, make sure that the mains voltage complies with the specifications on the rating plate. 
Long  supply  cables,  extensions,  cable  reels  etc.  cause  a  drop  in  voltage  and  can  impede 
motor start-up. In the case of low temperatures below +5°C, motor start-up is jeopardized as a 
result of stiffness. 

Содержание POWERPLUS POWX1730

Страница 1: ...lasting guns 5 5 2 Safety information for paint spraying 5 5 3 Operating pressure vessels 6 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR 6 7 ASSEMBLY AND STARTING 6 7 1 Fitting the wheels 3 6 7 2 Fitting the supporting foot 4 6 7 3 Voltage 6 7 4 On Off switch 8 7 7 5 Adjusting the pressure Fig 2 7 7 6 Setting the pressure switch 7 8 CLEANING AND MAINTENANCE 7 8 1 Cleaning 7 8 2 Condensation wat...

Страница 2: ...POWX1730 EN Copyright 2015 VARO P a g e 2 www varo com 13 ENVIRONMENT 9 14 DECLARATION OF CONFORMITY 10 ...

Страница 3: ...packing materials Remove remaining packaging and transit supports if existing Check the completeness of the packing content Check the appliance the power cord the power plug and all accessories for transportation damages Keep the packaging materials as far as possible till the end of the warranty period Dispose it into your local waste disposal system afterwards WARNING Packing materials are no to...

Страница 4: ...ing pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoidable use a residual curren...

Страница 5: ...hese instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work to be performed Use of the power tool for operations different from intended could lead to a hazardous situation 4 5 Service Have your power tool serviced by a qualified repair person using only identical replacement parts This will ensure that the safety of th...

Страница 6: ...e then please contact the customer service workshop 6 POINTS TO NOTE WHEN SETTING UP THE COMPRESSOR Examine the machine for signs of transit damage Report any damage immediately to the company which delivered the compressor The compressor should be set up near the working consumer Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the ...

Страница 7: ...sure We recommend that you clean the appliance immediately after you use it Clean the appliance regularly with a damp cloth and some soft soap Do not use cleaning agents or solvents these may be aggressive to the plastic parts in the appliance Ensure that no water can get into the interior of the appliance You must disconnect the hose and any spraying tools from the compressor before cleaning Do n...

Страница 8: ... standard K 3 Acoustic pressure level LpA 77 dB A Acoustic power level LwA 97 dB A ATTENTION Wear hearing protection when sound pressure is over 85 dB A 11 POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES FAULT CAUSE REMEDY The compressor does not start 1 No supply voltage 1 Check the supply voltage the power plug and the socket outlet 2 Insufficient supply voltage 2 Make sure that the extension cab...

Страница 9: ...time no claim can be made on the warranty if the damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage on purpose or by gross carelessness inappropriate usage use for purposes for which the device is not suitable incompetent usage e g not following the ins...

Страница 10: ...n of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2004 108 EC 2006 42 EC 2000 14 EC Annex VI LwA 94dB A 97dB A Testing Authority Eurofins Modulo Uno Torino IT European harmonized standards including if applicable their amendments up to the date of signature EN1012 1 2010 EN60204 1 2006 EN55014 1 2006 EN5501...