10 TECHNICAL DATA
Rated voltage
230-240V
Rated frequency
50Hz
Power
1050W
No
– load speed
5500 min
-1
Max. cutting depth
30mm
Saw blade diameter
125mm
Teeth
32T
Protection class
Double insulated
Rated operation
Continuous operation
11 NOISE
Noise values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
98 dB(A)
Acoustic power level LwA
112 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in this case
individual hearing protection shall be worn.
aw (Vibration)
Max. 2.8 m/s²
K = 1,5 m/s²
12 SERVICE DEPARTMENT
Damaged switches must be replaced by a qualified technician.
If the connecting cable (or mains plug) is damaged, it must be replaced by a particular
connecting cable which is available from our service department. Replacement of the
connecting cable must only be carried out by our service department (see last page) or by
a qualified person (qualified electrician).
13 STORAGE
Thoroughly clean the whole machine and its accessories.
Store it out of the reach of children, in a stable and secure position, in a cool and dry
place, avoid too high and too low temperatures.
Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
Don’t keep it in plastic bags to avoid humidity build-up.
14 TROUBLESHOOTING
Problem
Cause
Solution
Very high spark generation
1.
Damaged teeth
2.
Feed speed is too slow
3.
Blunt teeth
1.
Replace blades
2.
Increase feed speed
3.
Replace blades
A lot of wear in sections
1.
Feed speed is too fast
2.
Damaged teeth
3.
Blunt teeth
4.
Not cutting parallel or
perpendicular to work
surface
1.
Reduce the feed speed
2.
Replace blades
3.
Replace blades
4.
Hold saw parallel to
work surface
Blades are breaking
1.
Damaged teeth
2.
Feed speed is too fast
3.
Blunt teeth
1.
Replace blades
2.
Reduce feed speed
3.
Replace baldes