5  GENERAL POWER TOOL SAFETY WARNINGS 

Read  all  safety  warnings  and  all  instructions.  Failure  to  follow  all  warnings  and  instructions 
may  result  in  electric  shock,  fire  and/or  serious  injury.  Save  all  warnings  and  instructions  for 
future reference. The term "power tool" in the warnings refers to your mains operated (corded) 
power tool or battery operated (cordless) power tool. 

6  BEFORE START-UP, NOTE THE FOLLOWING! 

 

The pump can be connected to any shock-proof plug which has been installed according 
to regulations. The plug must have a supply voltage of 230 V ~ 50 Hz. Fuse min. 6 Amp. 

Caution!  

When  the  pump  is  to  be  used  near  swimming  pools  or  garden  ponds  and  in  their  area  of 
protection, it must be equipped with a PRCD (residual current circuit breaker) with a nominal 
trip current of max. 30 mA (according to VDE 0100, part 702 and 738). The pump must not be 
operated while people are in the swimming pool or in the garden pond!  Please contact your 
electrician! 

Attention! 

(Important  for  your  own  security)  Before  starting  to  run  your  new  submersible  pump,  please 
have the following items checked by an expert: 

 

Ground connection 

 

Zero conductor 

 

Fault current breaker switch must correspond the safety regulations of the power plants 
and they must work faultlessly. 

 

The electrical connections must be protected from moisture. 

 

If there is danger of flooding, the electrical connections must be taken to higher ground. 

 

Circulation of aggressive fluids, as well as the circulation of abrasive materials must be 
avoided at all costs. 

 

The submersible motor-driven pump must be protected from frost. 

 

The pump must be protected from running dry. 

 

Access on the part of children should also be prevented with appropriate measures. 

Consistency 

Your submersible pump is designed for the circulation of water with a maximum temperature 
of  35°  C.  This  pump  may  not  be used for  other fluids,  especially motor  fuels,  cleaning fluids, 
and other chemical products! 

7  INSTALLATION 

The submersible pump is installed as follows: 

 

In a stationary position with fixed pipeline 

or 

 

in a stationary position with a flexible hose pipe. 

Please note! 

You  should  never  install  the  pump  by  suspending  it  unsupported  from  its  delivery  pipe  or 
power cable. The submersible pump must be suspended from the specially provided handle or 
be placed on the bottom of the shaft. To guarantee that the pump works properly, the bottom 
of the shaft must be kept free of sludge and dirt of all kinds. 
If the level of water sinks too far, any sludge in the shaft will dry out quickly and stop the pump 
from starting up. ,Therefore it is necessary to check the submersible motor pump regularly (by 
carrying out start-up tests). The floater is adjusted in a way that the pump can immediately be 
started 

Note! 

The  pump  shaft  should  have  minimum  dimensions  of  40  x  40  x  50  cm,  so  that  the  floating 
switch can move freely. 

 

 

Содержание Powerplus POWEW67906

Страница 1: ...BEFORE START UP NOTE THE FOLLOWING 3 7 INSTALLATION 3 8 SETTING TO WORK 4 8 1 Venting the pump before use 4 8 2 Setting the ON OFF operating point 4 9 CLEANING AND MAINTENANCE 4 9 1 Maintenance guide...

Страница 2: ...le plug 5 floating switch 6 carrying handle 7 cable clamp 3 PACKAGE CONTENT LIST Remove all packing materials Remove remaining packaging and transit supports if existing Check the completeness of the...

Страница 3: ...cted from moisture If there is danger of flooding the electrical connections must be taken to higher ground Circulation of aggressive fluids as well as the circulation of abrasive materials must be av...

Страница 4: ...h can be set by adjusting the float switch in its latching holder Before you put the pump into operation please check the following The float switch must be installed so that the level of the ON opera...

Страница 5: ...ump as follows 1 Remove the intake cage from the pump case 2 Clean the impeller with clear water Important Do not put down or rest the pump on the impeller 3 Re assemble in reverse order 10 TECHNICAL...

Страница 6: ...acity by dirty and abrasive water Clean inlet sieve Clean pump and replace worn out parts Pump switches off after short operating period Thermal cutout stops pumps due to dirty water Water too hot The...

Страница 7: ...damage of the device is the result of negligent maintenance or overload Definitely excluded from the warranty is damage resulting from fluid permeation excessive dust penetration intentional damage o...

Страница 8: ...nized standards Any unauthorized modification of the apparatus voids this declaration European Directives including if applicable their amendments up to the date of signature 2011 65 EU 2014 35 EU 201...

Отзывы: