MAINTENANCE
WARNING: Disconnect wrench from air supply before changing
accessories, servicing or performing maintenance. Replace or repair
damaged parts. Use genuine parts only. Non-authorized parts may be
dangerous
1.
Lubricate the air tool daily with a few drops of air tool oil dripped into the air inlet
2.
DO NOT use worn, or damaged tool.
3.
Loss of power or erratic action may be due to the following:
4.
Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size
or type of hose connectors. To remedy check the air supply.
5.
Grit or gum deposits in the tool may also reduce performance. If your model has an
air strainer (located in the area of the air inlet), remove the strainer and clean it.
6.
When not in use, disconnect from air supply, clean tool and store in a safe, dry,
childproof location.
11
TECHNICAL DATA
Model
POWAIR0803
Blows per minute
4500min-1
Operating pressure
6.2bar / 90psi
Air inlet size
¼”
Avg. air consumption
142l/min
Chisel shank
2/5”
Bore diameter
¾”
12
NOISE
Noise values measured according to relevant standard. (K=3)
Acoustic pressure level LpA
94 dB(A)
Acoustic power level LwA
105 dB(A)
ATTENTION! The sound power level may exceed 85 dB(A), in this case
individual hearing protection shall be worn.
aw (Vibration)
167,8m/s²
K = 7,9 m/s²
13
TROUBLE SHOOTING
The following form lists the common operating system with problem and solutions. Please
read the form carefully and follow it.
WARNING: If any of the following symptoms appears during your
operating, stop using the tool immediately, or serious personal injury