- 7 -
3. Calibrate Menu
The Calibrate menu is where you will calibrate the motor to the
current lens that you are using. For all lenses that have stop points (most ENG and
cinema lenses), after you have mounted the motor to the lens tap the “Automatic” button,
and the motor will automatically move to both ends of the lens range, and then the lens is
calibrated. For lenses that don’t have stop points (most DSLR lenses), manual calibration
is required.
Tap “Manual” to enter the calibrate screen (as shown to the
left). Move the slider to the center position as indicated on the
screen – a center mark will appear and further instructions will
be shown on the screen. The slider will now be used to run
the motor until the first end point of the lens is reached. The
farther you move the slider, the faster the motor will go, so
when you get close to the stopping point, slow the motor down by moving the slider back
toward the center position – the motor stops moving when the slider is at the center
position. If you move the motor too far, you can reverse it by moving the slider in the
opposite direction past the center position – this will move the lens back (stop the motor
by returning slider to center position). When the first end point is reached on the lens, tap
the “OK” button. Now move the slider in the opposite direction to find the other end
point for the lens. Stop the motor at the correct end point for the lens, and tap the “OK”
button again. The lens motor is now calibrated, and you will automatically be returned to
the home screen