Variotech NSE Скачать руководство пользователя страница 4

 

Manual and Data Sheet NSE Version 1.0 

 

Variotech – Emergency power supply unit NSE Version 1.0

 

Date: 10.01.14, Page 4 of 7 

 

Product description: 

 

Compact and reliable power supply unit for A3 safety elements with power supply 24VDC. 

 

Built-in logic for the function of an uninterruptible power supply. 

 

Built-in logic for safe shutdown of the A3 brake element if an A3 error occurs. 

 

Connection for external emergency release button with built-in logic and  
output terminals to reset the A3 safety circuit. 

 

Clamp connection for a 12V battery (to load). 

 

Built-in monitoring of charging and deep discharge protection of the battery. 

 

Relay contact output for message if battery is OK or defective. 

 

Built-in logic for switching between battery charging and supply 

 

Built-in function to create a buffer voltage of 24VDC from the 12V battery.  
This only requires a single 12V battery. 

 

Reverse polarity protection and automatic reset fuse at the battery clamp. 

 

Automatic lowering of the supply voltage of the A3 brake element after tightening of the 
anchor. This causes a reduction of the heating of the coil of the A3 brake element and an 
improvement of the overall life and reliability of the A3 device. 

 

Input for monitoring the mains voltage 

 

Signal transducer (beeper / buzzer) for signalling of faults acoustically.  
This makes it easier for the technician to find an error. 

Layout and connections: 
 

Technical Details: 

Connection: with plug-in terminals, encoded with different numbers, 
Terminals: max. conductor cross section of 1 mm

²

 with sleeve, or 1.5 mm

²

 without sleeve. 

Cable length: There are no prescribed limits. Shielded cables are not necessary. 

 
Operating ambient temperature:   

+ 5°C to + 40°C 

Humidity (no condensation) 

 

< 95 % 

Storage temperature:   

 

– 25°C to + 70°C 

Dimensions:     

 

 

10cm x 12cm x height 5cm 

Weight:  

 

 

 

500g

 

Содержание NSE

Страница 1: ...and liability management 3 Intended use 3 Commercial data 3 Product details 3 Function 3 Product description 4 Layout and connections 4 Technical Details 4 Environmental conditions 5 Conditions of us...

Страница 2: ...er a 24V power supply and battery backup NSE The power supply NSE requires an input voltage of 13 6 V DC galvanically isolated from the mains power supply The power supply NSE generates the charging v...

Страница 3: ...in of other systems or particular in industrial plants The safety control ENA3 may only be used for the case defined in EN81 Annex 3 to prevent of an unintendend movement of the car from a standstill...

Страница 4: ...oltage of 24VDC from the 12V battery This only requires a single 12V battery Reverse polarity protection and automatic reset fuse at the battery clamp Automatic lowering of the supply voltage of the A...

Страница 5: ...itable power supply would be Meanwell MDR 40 12 Terminal 3 Connection for the potential free output contact relay power ok of the power supply Terminals 4 5 Connection for a safety relay contact of th...

Страница 6: ...continuity tester If the battery is OK the two terminals have the same potential Check the correct connection of the emergency rescue button to terminals 14 and 15 with a continuity tester Terminal 1...

Страница 7: ...talled in a control box On request the unit can also be supplied already mounted in an industrial plastic housing IP65 The complete system ENA3 NSE BOX consists of a pre wired and pre assembled ENA3 c...

Отзывы: