12
11
Active Attenuation - Criterion Levels
EN352-7 Minimum Requirements
Measured Results
H
L
97dB(A)
94dB(A)
110dB(A)
107dB(A)
M
96dB(A)
110dB(A)
Passive Attenuation
SD (dB)
7.6
5.3
4.2
3.2
5.6
5.4
8.1
F (Hz)
63
250
500
1000
2000 4000 8000
125
MA (dB)
24.9
21.9
24.1
24.4
29.3
32.8
30.1
25.0
7.6
APV (dB)
17.3
16.6
19.9
21.2
23.7
27.4
22.0
17.4
Silicone Moulds
H
M
L
24dB
SNR
21dB
19dB
24dB
F = Frequency
MA = Mean Attenuation
SD = Standard deviation
APV = Assumed protection level
H = High frequency attenuation
M = Medium frequency attenuation
L = Low frequency attenuation
SNR = Single Number Rating attenuation
Attenuation information
Vario Hearables Ltd declares that the hearing protection is in
compliance with PPE regulation EU 2016/425.
The full text of the EU declaration of conformity can be found at
www.variohearables.com.
The certification according to PPE Regulation (EU) 2016/425 and
the production control module D (CE2777) were performed by
Satra Technology Europe Ltd, Bracetown Business Park, Conne,
D15 YN2P, Ireland, #2777. The Approved Body responsible for
certification and Module D according to Regulation (EU) 2016/425
as retained in UK Law and amended is SATRA Technology Centre
Ltd (AB0321), Wyndham Way, Telford Way, Kettering,
Northamptonshire, NN16 8SD, UK, #0321.
EN 352-2:2002 and EN352-7:2002