The mixer
requires no maintenance (motor and bearings for the
mechanical parts are greased for life).
Safety device:
Check the function of the safety device regularly:
•
The motor
must stop when the rotary knobs is in neutral
position
(see fig. 3B)
.
If the safety device does not function, do
not use the mixer. Contact your dealer.
l
IsT
of
Errors
AnD
possIblE
soluTIons
:
If the problem cannot be solved, contact
your dealer.
The mixer does not start:
Check that ...
•
The upper part of the mixer is in its down position.
•
The mixer is plugged in and connected to power.
•
The electrical power supply is correct.
•
The fuse in the cable plug
(fig.6, 1)
has not been burned.
If the fuse is defective, it can be replaced by the extra fuse
(fig.6, 2)
that is also available in the cable plug.
The mixer stops during work:
•
The mixer is overloaded due to too high speed or too
heavy loading. See the paragraph
“Overloading”
.
In case of power failure set the rotary but-
ton back to neutral position, and the mixer
can be started again.
The tool is stuck in the bayonet shaft:
This is normally due to insufficient cleaning or damaged hole in
the tool:
•
When the tool is stuck, do not force it free. Apply a little
oil and let this work a couple of minutes.
•
Turn the tool backwards and forwards until it can be removed.
Unnormal noise:
Metallic noise ...
•
The tool is distorted and hits the bowl.
•
The bowl has been damaged or is not in its proper position.
m
ounTInG
of
ACCEssorIEs
:
The mixer is equipped with an attachment hub with variable speed,
and with the possibility of attaching the following equipment:
•
Meat grinder , supplied with meat tray, stomper and set of
knives consisting of blade and plate 5/32”.
For further information regarding accesso-
ries, please see the special sheets following
the accessories.
The mixer must always be disconnected
before mounting or dismantling of the ac-
cessory.
Mounting of accessories (fig. 7):
•
Assemble the accessory.
•
Stop the mixer.
•
Turn the cover plate
C
away from the hole.
•
When mounting the pre-mounted accessory
A
, the shaft
B
is inserted into the attachment drive
D
of the mixer.
•
By turning the accessory until the pin
E
is pointing towards
the slot
G
a correct clutch is obtained.
•
The accessory is pushed as far into the attachment hub
D
as possible. (The pin
E
must be in the slot
G
, then the shaft
of the accessory is in a correct clutch with the attachment
drive).
•
The accessory is fastened by turning the knob
H
clockwise.
Dismantling of accessories (fig. 7):
•
Stop the mixer.
•
Turn the knob
H
counterclockwise until the locking screw is
free of the hole
F
.
•
Take out the accessory of the attachment hub, dismantle and
clean it.
Fig. 7 Mounting of accessories.
r
ECommEnDED
spEEDs
for
ATTAChmEnT
hub
:
Fig. 6 Fuses in the cable plug.