background image

Systematic maintenance:

Part

Action

Frequency

Note

Safety guard

Check the safety of the safety guard: 

Does the tool stop rotating (< 4 sec.)

when the guard is tilted/removed?

Regularly

I

f any malfunction,

 

please contact a technician

Emergency stop

Test the emergency stop: Does the 

tool stop rotating (< 4 sec.) when the 

emergency stop is activated?

Regularly

 I

f any malfunction,

 

please contact a technician

Mixer head

The mixer head should only be lubri-
cated on repair, see the section 

“Lu-

brication and grease types”

.

During repairs

The machine’s oth-
er moving parts

The moving parts that belong to the 
bowl’s lifting mechanism all run in 
maintenance-free plain bearings and 
should not therefore be lubricated.

Never

Attachment drive

The rubber plug for covering the open-
ing of the attachment drive should be 
on the machine and be intact.

Daily

The rubber plug must cover 

the opening on the attachment 
drive when the latter is not in use.

Cleaning

Follow the instructions in the section 

“Cleaning”

Follow the instructions in 
the section “Cleaning”

Lubrication and grease types:

Lubrication and other servicing may only be carried out by trained staff over 14 years of age.

The lid of the mixer may only be removed when the cable to the mains supply has been removed.

When repairs are made to the mixer head, the gear wheel and internal gear should be lubricated with 

Molykote G-1502 

FM

 the needle bearings in the mixer head can also be lubricated with this type of grease. 

If the machine is supplied with an attachment drive, the gear for the attachment drive should be lubricated with 

Renolit 

GreaseWay LiCa 80

.  

Do not use any other grease types than those specified above.

Overloading:

The mixer must not be overloaded. 

Possible overload situations:

• 

Working with excessively tough and heavy dough 

• 

Mixer tool exceeding the recommended speed

• 

Wrong mixer tool being used. 

Larger lumps of fat or chilled ingredients must be reduced before they are placed in the bowl.

Overloading will cause the 

VFD (variable frequency drive)

 to stop the machine. 

 or 

 

will be displayed in the timer field.

Follow the description under “

Procedure in case of overloading”

.

Procedure in case of overloading:

Spot the error code in the section 

“Error codes and possible solutions”, 

and follow the suggestion for a solution. 

When done, remove the error code by pressing 

.

The mixer can now be restarted by pressing 

.

12

Содержание KODIAK20

Страница 1: ...K KODIAK 20 KODIAK30 Varimixer A S Elementfabrikken 9 DK 2605 Br ndby Denmark P 45 4344 2288 E info varimixer com www varimixer com Operating Instructions EN DRN 20020 1602 Original user manual 2022 0...

Страница 2: ...packaging disposed of according to regulations applicable in the country concerned Before the machine is removed from the pallet check that all parts are present with the machine Safety guard and fil...

Страница 3: ...r To ensure this you must measure the distance from the top of the ma chine to the floor The dimension must be the same when measured at the front of the mixer and at the rear of the mixer Condition 2...

Страница 4: ...dual current device is required by the installation standards a type A circuit breaker should be used User can connect machine if Cable with plug is delivered with the machine Only certified electrici...

Страница 5: ...stop The tool stops rotating in less than 4 seconds also for normal shut down and stop via safety guard Clearance between guard stand and lifting handle at least 50 mm Machine remains stable even if t...

Страница 6: ...at tached see page 3 Lifting handle Bowl truck Only floor model Bowl Control panel Safety guard Mixer head Mixer tool Control panel with attachment drive Adjustable legs see page 3 for adjustment Bowl...

Страница 7: ...d is made of transparent plastic The guard is easy to remove and clean The guard can be machine washed at up to 60 C and can withstand up to 90 C for short periods The loose silicone filling chute wit...

Страница 8: ...nameplate 50 60 Hz 20 Floor model 30 Floor model Table model Dimensions KODIAK 20 Floor model Dimensions KODIAK 30 8 kg kg kW Volts Amps 97 72 0 7 64 353 179 154 220 195 1 2 745 442 486 533 67 482 72...

Страница 9: ...kg Layer cake base Whip 5 0 kg 7 0 kg Meat ball mix Beater 15 kg 20 kg Icing Beater 14 kg 20 kg Doughnut 50 AR Hook 12 5 kg 15 kg Local variations in the characteristics of the ingredients can influe...

Страница 10: ...rt the mixer by pressing Display of running time Timer function Select a running time for the mixer by pressing next to The running time is shown in minutes and seconds in the timer field between and...

Страница 11: ...temperatures for extended periods of time General maximum temperature 60 C rinse maximum 90 C for a maximum of 30 seconds To assist in the preparation of customer specific cleaning plans Varimixer A...

Страница 12: ...ther servicing may only be carried out by trained staff over 14 years of age The lid of the mixer may only be removed when the cable to the mains supply has been removed When repairs are made to the m...

Страница 13: ...ntermittent low voltage in the power supply Solution Contact a technician to control the power supply to the mixer EE 10 Intermittent high voltage in the power supply Solution Please contact a technic...

Страница 14: ...1 234 min or a total running time of 21232 min Data set 4 States the number of times the machine has been disconnected from the power supply plug pulled out of the machine powercut switched off and re...

Страница 15: ...evet Sidst rettet Siderev Projektrev Godk dato init Konstr projekt side Tegningsnr Sagsnr Projekttitel Kunde Sidetitel Filnavn Sideref DCC M lestok Kodiak VL1C 5 13 12 04 2021 Diagram PCSCHEMATIC Auto...

Страница 16: ...risk Direct food contact zone High risk Cleaning step by step Bowl Empty the bowl and rinse with water Put bowl in the dishwasher or wash by hand with a soft sponge or brush Tools Remove any food res...

Страница 17: ...chlorides and other chemicals will be higher than during the cleaning process Always rinse and wipe off the mixer with clean water of drinking water quality after using chemicals All oxidising chemic...

Страница 18: ...t hiermede dat Menger Declaramos que el producto batidora er i overensstemmelse med relevante bestemmelser i Maskindirektivet Direktiv 2006 42 EC is in conformity with the relevant provisions of the M...

Страница 19: ...lanetaarmikseri Niniejszym o wiadczamy e mikser planetarny vakuuttaa ett t m mikseri tyyppi S tem dokumentom izjavljamo da je ta me alnik verensst mmer med till mpliga best mmelser i maskindirektivet...

Страница 20: ...Varimixer A S Elementfabrikken 9 DK 2605 Br ndby P 45 4344 2288 E info varimixer com www varimixer com...

Отзывы: