14
9.2 Light Indicator
The LED indicator lights red during the Gripping / closing function, when the tool has gripped to the preset
holding pressure, the LED indicator lights green.
9.3 Adjustments
The gripping pressure needs to be preset in the PLC settings, to suit the item that is handled.
The rotational speed can be adjusted in the PLC settings.
9.4 Adjusting speed and Amps for gripping unit
Parameters should only be adjusted by skilled technicians, as
improper procedures may lead to insufficient clamping power
and/or irreversible motor damage.
The following parameters may be adjusted in the control box:
P3:
Used for adjusting amps on gripping (clamping force)
P4:
Gripping speed
P6:
Turning speed
Содержание Flexlift INOX mini
Страница 18: ...18 14 Electrical chart ...
Страница 29: ...29 ...
Страница 30: ...30 ...
Страница 31: ...31 ...