VARILITE VLZ SPOT Скачать руководство пользователя страница 3

Compliance & Safety Notices 

Compliance

This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. 
These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  when  this  equipment  is  operated  in  a 
commercial  environment.  This  equipment  generates,  uses,  and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in 
accordance with Vari-Lite system, service, and safety guidelines, may cause harmful interference to radio communications. 

As tested under this standard: 

FCC 47CFR 15B clA*CEI 

Issued:2009/10/01 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A 

Operation  of  this  equipment  in  a  residential  area  is  likely  to  cause harmful  interference,  in  which  case the  user  will  be  required  to 
correct the interference at his/her own expense.   

EC Declaration of Conformity 

We, 

Vari-Lite 

B.V., 10911 Petal Street, Dallas, Texas 75238, declare under our responsibility for the products contained herein are  in 

conformity  with  the  essential  requirements  of  the  following  European  Directives  and  harmonized  standards:  Low  Voltage 
Director (LVD), 2006/95/EC EN 60589-2-17:1984+A1:1987+A2:1990 used in conjunction with 60598-1:2008/A11:2009 
Electromagnetic Compatibility Directive (EMC), 2004//108/EC EN 55022:2010, EN55024:2010

 

Safety Notice 

It is extremely important to read ALL safety information and instructions provided in this manual and any accompanying documentation before 
installing and operating the products described herein. Heed all cautions and warnings during installation and use of this product. Safety symbols 
used throughout this manual are as follows:   

CAUTION advising of potential damage to product.

 

WARNING advising of potential injury or death to persons. 

GENERAL INFORMATION PERTAINING TO PROTECTION AGAINST ELECTRICAL SHOCK, FIRE, EXPOSURE TO EXCESSIVE UV 
RADIATION, AND INJURY TO PERSONS CAN BE FOUND BELOW.   

WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST FIRE 

1

 

Luminaires may be mounted on any type of surface as long as mounting instructions are followed. See instructions detailed in this manual. 

2

 

Note distance requirement from combustible materials or illuminated objects for VARI

LITE luminaires.   

WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST ELECTRICAL SHOCK 

1

 

VARI

LITE luminaires are designed for dry locations only. Exposure to rain or moisture may damage luminaire. 

2

 

Disconnect power before servicing any VARI

LITE equipment.   

3

 

Servicing to be performed by qualified personnel only.   

WARNING: INSTRUCTIONS FOR CONTINUED PROTECTION AGAINST EXCESSIVE 
EXPOSURE TO UV RADIATION 

 

1

 

It is hazardous to operate luminaires without lens or shield. Shields, lenses, or ultraviolet screens shall be changed if they have become   

visibly damaged to such an extent that their effectiveness is impaired. For example, by cracks or deep scratches. Replace any cracked or 

protective shields.   

FCC

Содержание VLZ SPOT

Страница 1: ...1 ...

Страница 2: ...commended Practice for DMX512 A Guide for Users and Installers 2nd edition ISBN 9780955703522 USITT Contact Information USITT 315 South Crouse Avenue Suite 200 Syracuse New York 13210 1844 USA Phone 800 938 7488 or 1 315 463 6463 Fax 866 398 7488 or 1 315 463 6525 Web Site www usitt org Customer Service Our Goal At Vari Lite we are committed to providing you the highest quality in customer service...

Страница 3: ...mportant to read ALL safety information and instructions provided in this manual and any accompanying documentation before installing and operating the products described herein Heed all cautions and warnings during installation and use of this product Safety symbols used throughout this manual are as follows CAUTION advising of potential damage to product WARNING advising of potential injury or d...

Страница 4: ...ES L EXPOSITION EXCESSIVE AUX RAYONS UV ET TOUT AUTRE ACCIDENT POUVANT ENTRAÎNER DES BLESSURES AVERTISSEMENT DIRECTIVES POUR SE PROTÉGER CONTRE LES INCENDIES 1 Les luminaires peuvent être fixés sur tout type de surface tant que les directives de montage sont respectées Voir les explications détaillées dans ce guide 2 Vérifier la distance à respecter entre les matériaux combustibles ou les objets i...

Страница 5: ...équates Other Battery Information Informations sur la batterie This unit has a battery Warning Caution risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Cet appareil dispose d une batterie Avertissement Attention risque d explosion si la batterie de remplacement par un type incorrect Jetez les piles usageesselon les instructions ...

Страница 6: ...stration shows all items included with the luminaire Figure 1 VLZ SPOT Luminaire Included Items Note Please Check with the local Vari Lite Office or Authorized Vari Lite dealer for availability on accessories QuickStart Guide this document Neutrik powerCON True1 AC Input Connector ...

Страница 7: ...e or construct a cable appropriate for your application Figure 2 Power Connector Depending on the application the luminaire s AC input cable may require a different connector If required install a new connector meeting your requirements using the following wire color code reference Wire Connection Green AC Ground White AC Neutral Blcak AC Line International Harmonized Standard WARNING DO NOT conne...

Страница 8: ...ected to an AC source the unit operates on 100 to 240 volts AC 10 auto ranging The luminaire contains an auto ranging power supply Each luminaire can draw up to 850 Watts WARNING It is the responsibility of the user to adequately protect supply source with a correct size and type circuit breaker and not overload circuits AVERTISSEMENT Il est de la responsibilité de l utilisateur de protéger adéqua...

Страница 9: ...Figure 3 Data Link Step 4 Connect AC Input Cable connector to power input source Step 5 Dress AC input and data cables and secure them so that they will not interfere with luminaire head and yoke movement ...

Страница 10: ...wo hooks per luminaire is required If mounting method does not use truss hooks two attachment points per luminaire are required Install mounting hardware and brackets Step 1 Install truss hooks on two provided truss hook brackets as required as shown in Figure 4 Step 2 Determine required configuration of bracket installation Brackets may be installed in many different orientations as shown in Figu...

Страница 11: ...11 Figure 5 Installing Brackets on Luminaire Enclosure ...

Страница 12: ...t panel If there are multiple luminaires in a system any settings or changes would need to be made at each LCD Menu as desired Menu Controls The menu system is controlled by an MODE ESC and four Arrow buttons These buttons function are shown in Figure 6 Figure 6 Menu Controls LCD Display and Menu System Operation The LCD Display Menu system consists of several categories Use the Menu Buttons to ac...

Страница 13: ...y commands that require full power calibrate etc will be ignored while the menu system is in battery operation mode Step 3 To exit battery mode press MODE ESC three seconds Status Bar The Status Bar as illustrated in Figure 7 is present at all times and displays luminaire operational information of the luminaire The Status Bar contains the following information LED indicates current lamp state ON ...

Страница 14: ...f fixture zoom range between 9 High Byte 0 narrow to 65535 wide 10 Low Byte 11 Programming 0 255 0 Used as a control channel for different programmable settings Control Set value of desired effect 0 2 Idle 3 5 Linear Dimming Curve 6 10 Square Law Dimming Curve 11 15 TV Dimming Curve 16 20 Architectural Dimming Curve 51 55 Edge Track ON 56 60 Edge Track ON 61 65 Edge Track ON 66 70 Edge Track OFF C...

Страница 15: ...escription 21 Color Wheel 1 0 255 0 Used as a control channel for different movement options of Color Control Wheel 1 0 5 Linear Movement using shortest quickest path 6 10 Linear Movement using normal longest path 11 15 Wheel Spin Forward Fast to Slow 16 20 Wheel Spin STOP 21 25 Wheel Spin Reverse Slow to Fast 26 56 Color Shake Quickest Path Slow to Fast 57 87 Color Shake Normal Path Slow to Fast ...

Страница 16: ...r Shake Normal Path Slow to Fast 88 255 Reserved Values 24 Gobo Wheel 1 0 255 0 8 bit control of Gobo Wheel 2 See Channel 27 for control options Rotating Gobo Wheel 0 5 Open No Gobo 6 10 Gobo 1 Leafy Breakup Index 11 15 Gobo 2 Wavy Triangle Index 16 20 Gobo 3 Lattice Index 21 25 Gobo 4 Swirl Index 26 30 Gobo 5 Radial Breakup Index 31 35 Gobo 6 Neurons Index 36 40 Gobo 7 Grid Index 41 45 Open No Go...

Страница 17: ...ovement options for Control Gobo Wheel 1 Channel 24 0 5 Gobo Selection using shortest quickest path 6 10 Gobo Selection using normal longest path 11 20 Reserved Values 21 50 Wheel Spin Forward Fast to Slow 51 60 Wheel Spin STOP 61 90 Wheel Spin Reverse Slow to Fast 91 120 Gobo Shake Quickest Path Slow to Fast 121 150 Gobo Shake Normal Path Slow to Fast 151 180 Gobo Twist Quickest Path Slow to Fast...

Страница 18: ...e Rocks Rotate with Mega Stepping 121 255 Reserved Values Gobo 2 Rot Index 0 65535 32767 16 bit control of index and rotation of gobo wheel 1 29 High Byte 0 126 Rotate Fast to Slow 127 128 Rotation STOP 129 255 Rotate Slow to Fast 30 Low Byte DMX Channel Parameter Range DMX Defaults Description 31 Gobo Wheel 2 0 255 0 Used as a control channel for different movement options for Control Gobo Wheel ...

Страница 19: ... 100 Insert Light Diffusion 101 150 Insert Heavy Frost 151 200 Insert both Light Diffusion and Heavy Frost 37 Strobe 0 255 0 Controls Strobe functionality 0 3 Open 4 6 Closed 7 32 Normal Strobe Slow to Fast 33 58 Random Strobe Slow to Fast 59 84 Random Sync Slow to Fast 85 110 Pulse Slow to Fast 111 136 Pulse Random Slow to Fast 137 162 Pulse Random Sync Slow to Fast 163 188 Pulse Slow to Fast 189...

Страница 20: ...Full Luminaire ReCal Also Used to Wake fixture up from shutdown 11 15 Reserved Values 16 20 Reserved Values 21 25 Fixture Shutdown 26 30 Display Menu ON 31 35 Display Menu OFF 36 40 ReCal Position 41 45 ReCal Color 46 50 ReCal Gobo 51 55 ReCal Beam 56 60 ReCal Optics 61 65 ReCal Dimmer Strobe 66 70 Reset Fixture to Defaults See Manual for a list of factory defaults 71 75 Full Luminaire Reboot This...

Страница 21: ...21 ...

Страница 22: ...22 Vari Lite 10911 Petal Street Dallas Texas 75238 1 877 VARILITE 1 214 647 7880 www vari lite com ...

Отзывы: