Varilight Twin 13A Скачать руководство пользователя страница 2

 

EXAMPLE

 

WIRING

 ‐ 

1

 ‐

WAY

 

SWITCH

 

LIVE

 

 

SWITCHED

 

LIVE

 

For

 

2

 

or

 

more

 

gangs

 

the

 

live

 

wire

 

may

 

be

 

connected

 

to

 

each

 

COM

 

terminal

 

by

 

means

 

of

 

a

 

short

 

length

 

of

 

sleeved

 

wire.

 

WIRING

 ‐ 

2A,

 

5A,

 

13A

 

SOCKETS

 

All

 

sockets

 

must

 

be

 

earthed

 

and

 

check

 

earth

 

leads

 

adequately

 

sleeved.

  

Connect

 

the

 

earth

 

wire(s)

 

to

 

the

 

terminal

 

marked

 

with

 

an

 

earth

 

symbol.

  

Connect

 

the

 

live

 

wire(s)

 

to

 

the

 

terminal

 

marked

 

L.

  

Connect

 

the

 

neutral

 

wire(s)

 

to

 

the

 

terminal

 

marked

 

N.

 

EXAMPLE

 

WIRING

 ‐ 

2

WAY

 

SWITCHES

 

There

 

are

 

two

 

common

 

forms

 

of

 

wiring

 

for

 

2

way

 

circuits.

 

Either

 

may

 

be

 

used.

 

EXAMPLE

 

WIRING

 

DOUBLE

 

POLE

 

SWITCH

 

NEUTRAL

        

LIVE

 

 

FAN

 

ISOLATORS

 

Can

 

be

 

wired

 

using

 

the

 

above

 

configuration.

 

The

 

third

 

pair

 

of

 

terminals

 

should

 

be

 

used

 

for

 

fan

 

units

 

incorporating

 

timers.

 

WIRING

 

COAXIAL

 

SOCKETS

 

 

TELEPHONE

 

SOCKETS

 

Master

 

sockets

 

should

 

only

 

be

 

fitted

 

by

 

an

 

authorised

 

engineer.

 

When

 

fitting

 

a

 

telephone

 

slave

 

as

 

an

 

extension,

 

simply

 

connect

 

terminals

 

2,

 

3,

 

4

 

&

 

5

 

on

 

the

 

master

 

unit

 

co

 

the

 

same

 

terminal

 

number

 

on

 

the

 

slave

 

unit

 

with

 

the

 

same

 

cable

 

colour.

 

EXAMPLE

 

WIRING

 

 

INTERMEDIATE

 

SWITCHES

 

 

Fitting

 

Instructions

 

for

 

VARILIGHT

 

Wiring

 

Accessories

 

Please

 

read

 

these

 

instructions

 

carefully

 

before

 

beginning

 

any

 

electrical

 

work

 

and

 

retain

 

them

 

for

 

future

 

reference.

 

The

 

product

 

should

 

be

 

installed

 

in

 

accordance

 

with

 

the

 

current

 

addition

 

of

 

the

 

IEE

 

Wiring

 

regulations.

 

If

 

in

 

doubt,

 

consult

 

a

 

qualified

 

electrician.

 

1.

 

Always

 

switch

 

OFF

 

the

 

mains

 

supply

 

and

 

remove

 

the

 

appropriate

 

fuse

 

or

 

switch

 

off

 

the

 

appropriate

 

circuit

 

breaker

 

before

 

beginning

 

electrical

 

work.

 

2.

 

Always

 

use

 

cable

 

of

 

the

 

correct

 

rating

 

and

 

type.

 

3.

 

The

 

layout

 

of

 

the

 

terminals

 

may

 

differ

 

between

 

fittings

 

so

 

check

 

the

 

location

 

of

 

terminal

 

connections

 

carefully

 

before

 

wiring.

 

4.

 

Make

 

electrical

 

connections

 

according

 

to

 

the

 

relevant

 

diagram

 

ensuring

 

no

 

bare

 

wires

 

protrude

 

from

 

the

 

terminals.

 

Please

 

ensure

 

all

 

terminals

 

on

 

each

 

product

 

are

 

securely

 

tightened,

 

including

 

factory

 

tightened

 

terminals

 

5.

 

If

 

the

 

product

 

has

 

an

 

earth

 

terminal

 

connect

 

the

 

fixed

 

earth

 

wire

 

to

 

it

 

and

 

then

 

connect

 

a

 

short

 

length

 

of

 

wire

 

from

 

the

 

earth

 

terminal

 

on

 

the

 

product

 

to

 

the

 

earth

 

terminal

 

on

 

the

 

wall

 

box.

 

The

 

earth

 

wire

 

should

 

be

 

sheathed

 

with

 

green

 

and

 

yellow

 

sleeving.

 

6.

 

Screw

 

plate

 

to

 

wall

 

using

 

fixing

 

screws

 

supplied.

 

7.

 

Switch

 

on

 

the

 

mains

 

supply.

 

 

WARNING:

 

Do

 

not

 

apply

 

products

 

with

 

metal

 

faceplates

 

directly

 

to

 

freshly

 

plastered

 

or

 

damp

 

surfaces

 

as

 

product

 

may

 

tarnish.

 

If

 

in

 

doubt,

 

use

 

polythene

 

as

 

a

 

temporary

 

gasket

 

to

 

protect

 

the

 

product.

 

Do

 

not

 

use

 

masking

 

tape

 

on

 

metal

 

faceplates

 

EXAMPLE

 

WIRING

 

FUSE

 

HOLDER

EXAMPLE

 

WIRING

 

FUSE

 

HOLDER

 

USED

 

WITH

 

DOUBLE

 

POLE

 

SWITCH

 

 

METAL

 

GRIDPLATE

 

MUST

 

BE

 

EARTHED

 

USING

 

THE

 

TERMINAL

 

PROVIDED.

 

Guarantee:

 

If

 

this

 

item

 

becomes

 

defective

 

within

 

10

 

years

 

of

 

purchase,

 

Varilight

 

undertakes

 

to

 

repair

 

or

 

replace

 

the

 

item,

 

at

 

its

 

discretion,

 

and

 

solely

 

as

 

a

 

result

 

of

 

faulty

 

materials

 

or

 

workmanship,

 

provided

 

that

 

the

 

unit

 

has

 

been

 

correctly

 

fitted

 

according

 

to

 

the

 

instructions,

 

has

 

not

 

been

 

used

 

overloaded

 

beyond

 

its

 

rating,

 

tampered

 

with

 

or

 

taken

 

apart.

 

Pack

 

the

 

unit

 

securely

 

and

 

return

 

it

 

to:

 

Service

 

Department,

 

Carylls

 

Lea,

 

Faygate,

 

Horsham,

 

West

 

Sussex,

 

RH

 

12

 

4SJ

 

(Tel.

 

+44(01293)

 

223333),

 

together

 

with

 

a

 

letter

 

stating

 

the

 

guarantee

 

registration

 

number

 

below,

 

the

 

date

 

and

 

place

 

of

 

purchase,

 

the

 

type

 

and

 

wattage

 

of

 

the

 

lighting

 

or

 

other

 

load

 

being

 

controlled

 

and

 

the

 

details

 

of

 

the

 

fault.

 

This

 

guarantee

 

states

 

Varilight's

 

entire

 

liability,

 

which

 

does

 

not

 

extend

 

to

 

cover

 

consequential

 

loss

 

or

 

damage

 

or

 

installation

 

costs

 

arising

 

from

 

a

 

defective

 

product.

 

This

 

guarantee

 

does

 

not

 

in

 

any

 

way

 

affect

 

the

 

statutory

 

rights

 

of

 

the

 

purchaser

 

and

 

is

 

offered

 

so

 

that

 

you

 

may

 

have

 

the

 

benefit

 

of

 

our

 

technical

 

facilities.

 

Guarantee

 

Registration

 

Number:

 

WA005

 

Recycling

 

services

 

for

 

end

of

life

 

electrical

 

products

 

should

 

be

 

offered

 

by

 

your

 

local

 

authority.

 

Recycling

 

services

 

for

 

metal

 

faceplates

 

may

  

also

 

be

 

available

 

in

 

your

 

locality.

 

Doyle

 

&

 

Tratt

 

Products

 

Ltd

,

 

Carylls

 

Lea,

 

Faygate,

 

Horsham,

 

W.

 

Sussex,

 

RH12

 

4SJ,

 

UK.

 

+44

 

(01293)

 

223333

 

Varilight

 

Europe

 

Kft

,

 

2600

 

Vác,

 

Althann

 

Mihály

 

Frigyes

 

utca

 

2,

 

Hungary.

 

Отзывы: