Varian ProStar 500 

Column Valve Module 

Control 

Galaxie Driver Manual 

 

 

Содержание ProStar 500

Страница 1: ...Varian Inc 2700 Mitchell Drive Walnut Creek CA 94598 1675 USA Varian Inc 2002 2006 03 914947 57 1 Varian ProStar 500 Column Valve Module Control Galaxie Driver Manual...

Страница 2: ......

Страница 3: ...ver 4 Configuring the Driver 5 Configuring the Varian ProStar 500 CVM 5 Configuring the Synopsis 9 Building a Method 12 Creating a New Method 12 Control Method for the Varian Prostar 500 14 Starting a...

Страница 4: ...tion General This document describes the configuration of the Varian ProStar 500 Column Valve Module driver It also explains how to build a control method for this driver how to start and view a runni...

Страница 5: ...er To communicate with the ProStar 500 module an RS232_Interface or an RS232_PC communication bus must be configured on the acquisition server The bus parameters must be the following Stops 1 Stop Bau...

Страница 6: ...ProStar 500 CVM Click on the button corresponding to the Varian Prostar 500 driver and the configuration screen appears The toolbar allows you to easily scroll through the configuration windows to sel...

Страница 7: ...d with the Communication Server Configuration program The Varian ProStar 500 can have two modules A and B defined in its configuration Each module has a unique RS 422 ID to communicate with Define the...

Страница 8: ...sociate it with the module Galaxie is communicating with If the Heater is already associated to the module press the button to de associate it Enter the Maximum Temperature that can be reached by the...

Страница 9: ...press the button to associate it with the module Galaxie is communicating with If the Valve is already associated to the module press the button to de associate it Enter the name of the valve in the N...

Страница 10: ...the Overview part of the system configuration a synopsis can be defined for the system This synopsis depends on the configured devices 1 To save the configuration of these devices click on the OK but...

Страница 11: ...n to change the grid color 4 Once the synopsis configuration is complete it will be displayed in the Galaxie Chromatography Data System in the Systems tab In this tab the Overview part will show the s...

Страница 12: ...e system has been created and correctly configured it must be associated with one or more projects in order to start some acquisitions For more details about the creation and configuration of a system...

Страница 13: ...g of final results To initially set up a method it is not necessary to define all of the sub method sections however you must fill in the instrument control section prior to starting an acquisition 1...

Страница 14: ...New Method Name in the first field In the Description field enter information concerning the method optional 5 Once these two fields have been completed click on the OK button The new method is create...

Страница 15: ...he Galaxie Chromatography Data System User s Guide Control Method for the Varian Prostar 500 Once the new method is created select the control section in the lower part of the browser The following sc...

Страница 16: ...on to display Varian Prostar 500 control method section It contains two sub sections Program and Method Configuration Program Control Delay time parameter group In the Heater X delay field setting the...

Страница 17: ...end time all programmed changes will not be applied Enter the post run time to be applied in the Equilibration Time field Choose Reset in the Action field to apply to each valve and heater the prerun...

Страница 18: ...17 03 914947 57 1 Method configuration Control Heater X parameter group In the Maximum Temperature field the maximum temperature that was defined from the system configuration is displayed It is not...

Страница 19: ...up The configured name model and use of the valve are respectively displayed in the Name Model and Use field The valve connection is displayed in the table All theses settings can not be changed from...

Страница 20: ...trument control method has been correctly programmed an analysis can be started The next section briefly describes how to start an acquisition Quick Start Single Acquisition 1 Press the button In the...

Страница 21: ...Chromatography Data System the Injection Volume the Vial position and the Rack number if required must be entered Other parameters associated with each acquisition channel can be entered in the Channe...

Страница 22: ...of samples and the sequence name 2 The sequence is displayed Complete the sequence information columns refer to the Galaxie Chromatography Data System User s Guide The Method Name the Run Name the Run...

Страница 23: ...running chromatogram and the status window where the driver modules are listed Varian Prostar 500 CVM status Click on the button to display the Prostar 500 CVM status screen It contains five sub sect...

Страница 24: ...e Not Ready if the setpoints have not been achieved Running displays if the run is started or not and the current run time Communication Error displays if there is a communication failure Fault signal...

Страница 25: ...ed solvents are represented with the corresponding color A red marker indicates which the solvent in use is Click on to change the current valve Position and Delay Time in the following screen Heaters...

Страница 26: ...r is not yet associated press the button to associate it with the module Galaxie is communicating with If the Heater is already associated to the module press the button to de associate it Enter the M...

Страница 27: ...me field and select the model of the valve in the Model dropdown list Select the use of the valve in the Use dropdown list Finally complete the table depending of how the valve is connected If the sel...

Страница 28: ...valve module firmware is displayed Overview Window Click on the button the Status Overview window is displayed and contains three tabs General displays the synopsis of the instrument where the curren...

Страница 29: ...ProStar 500 Column Valve Module Manual 28 03 914947 57 1 Not Ready contains the not ready information sent by the instrument Events contains the events that have occurred on the instrument...