M
ENU
S
YSTEM
: M
ENU
F
UNCTIONS
02.9678.0019 0
31-July-2004
53
Index1
Gobo Index
Specifies rotating the gobo index for manual control (
Manual
) and testing (
Test
)
(EOT sensor, etc.)
Inv Pan
Invert Pan
Reverses pan action for special focus requirements.
Inv Tilt
Invert Tilt
Reverses tilt action for special focus requirements.
Lamp
Lamp
Accesses lamp power-up options, reset and information (
Config
) or prese the
Zoom and Edge to a specific setting for Lamp adjustment (
Test
).
Lamp OFF
Lamp is Off
Configures arc luminaire so that lamp will not strike upon power up.
Lamp ON
Lamp is On
Configures arc luminaire so that lamp will strike upon power u .
LampHour
Lamp Hours
Displays total number of lamp operating hours.
Lum Id
Luminaire ID
Displays unique luminaire ID number.
Magenta
Magenta
Specifies magenta parameter for manual control (
Manual
) or testing (
Test
).
Manual
Manual
Accesses options for luminaire mechanism cont ol y entry of data values.
Movement
Movement
Enables or disables pan and tilt movement
OFF
Off
Turns off a function.
OK
Okay
Indicates calibration has completed and o e ors have occurred.
OK?
Okay?
Prompt for pressing [Enter] befo e an act on is executed.
ON
On Indefinitely
Sets Menu Display to stay on ntil rogrammed otherwise (
Display
) or turns on a
function.
Pan
Pan
Specifies pan function for ma ual control (
Manual
) or testing (
Test
).
Pan/Tilt
Pan/Tilt
Accesses pan and tilt opti ns for focus swap function, movement enable/disable,
manual control an test ng.
PASS
Test Pass
Indicates that est has passed.
Power
Lamp Power
Accesses p ons to turn lamp on or off.
Power Up
Power Up
Accesses ptions for lamp power up state.
Program
Programming
Cur ently programming the new version of software.
Re-Cal
Recalibrate
R cali ates luminaire.
ResetDef
Reset Defaul s
Resets default system configuration values.
ResetLmp
Reset Lam
Resets lamp hour and strike counters. (For use when new lamp is installed.)
RotGobo
Gobo Whee 1
Specifies gobo wheel 2 (fixed gobo wheel) for manual control (
Manual
) and testing
(
Test
)
Rot Shut
Rotating Shutter
Specifies shutter mechanism rotating function for manual control (
Manual
) and test-
ing (
Test
)
RUN TEST
Run Test
Indicates that a mechanism test is in progress.
Sensor
Sensors
Accesses sensor types for diagnostic testing.
Setup
Setup
Accesses unit model type options (do not change).
Stat s
Status/Error
Allows scrolling through error list or displays
OK
if no errors.
S robe
Strobe
Specifies strobe function for manual control (
Manual
) or testing (
Test
).
STST
Sensor Test
Indicates that a system sensor test is in progress.
Swap
Swap
Swaps pan/tilt action for special focus requirements.
Test
Test
Accesses diagnostic tests for internal mechanisms.
Tilt
Tilt
Specifies tilt function for manual control (
Manual
) or testing (
Test
).
Version
Version
Displays current software version date and time (in two pages).
Zoom
Zoom Function
Specifies zoom function for manual control (
Manual
) or testing (
Test
).
Table 4-2: Menu Function Definitions (Continued)
Display
Definition
Purpose
www.carlosmendoza.com.mx
Содержание VL3500 SERIES
Страница 1: ......
Страница 4: ......
Страница 5: ......
Страница 7: ......
Страница 9: ......
Страница 11: ......
Страница 13: ...FOREWORD 02 9678 0019 0 31 July 2004 xi...
Страница 14: ...VARI LITE VL3500 SERIES LUMINAIRE USER S MANUAL xii 31 July 2004 02 9678 0019 0...
Страница 17: ......
Страница 24: ......
Страница 25: ......
Страница 26: ......
Страница 28: ......
Страница 29: ......
Страница 31: ......
Страница 44: ......
Страница 56: ......
Страница 60: ......
Страница 61: ......
Страница 71: ......
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......
Страница 78: ......
Страница 84: ......
Страница 85: ......