VL3000 Wash Luminaire - 1200W Metal Halide
Fixture output = 35,000 lumens. All data taken with a seasoned light source at 20 hours of life.
* Multiply throw distance by Tn to determine coverage.
** To calculate center beam illuminance (I) at a specific distance (D):
-- if (D) is in feet, (I) is in foot candles
-- if (D) is in meters, (I) is in lux
Diffusion
CANDELA
(cd)**
BEAM
ANGLE
(degrees)
BEAM
DIAMETER
TN*
FIELD ANGLE
(degrees)
FIELD
DIAMETER
TN*
Full Spot
1,253,000
7.5
0.131
14.0
0.246
25% Flood
495,000
10.0
0.175
22.0
0.389
50% Flood
178,000
18.0
0.317
37.5
0.679
75% Flood
94,100
25.0
0.443
49.5
0.922
Full Flood
61,100
30.5
0.545
60.0
1.155