DMX Input PCB Replacement
Parts:
24.9661.1251
1 EA
PCB ASSY, DMX INPUT
Tools:
Screwdriver, #2 Phillips
To remove and replace DMX Input PCB:
Step 1. Disconnect luminaire AC input cable from power source.
Step 2. At enclosure, remove power supply-side and ventilation covers. Refer to
“Removing Enclosure Covers” on page 35
Step 3. At DMX Input PCB, disconnect wiring connector (J3).
Step 4. At front connector panel, remove two M3
×
5mm LG PPB screws which
secure each DMX input connector to panel.
Step 5. Remove DMX input PCB Assembly.
Figure 2-29: DMX Input PCB Assembly Replacement
Step 6. Install replacement assembly by performing Steps 2–5 in reverse order.
DMX Input PCB
DMX Input PCB
Note:
Some components
not shown for clarity.
M3
×
5mm LG
PPB Screws (4)
Input Panel Inside View