M
AINTENANCE
: S
PECIAL
C
ONSIDERATIONS
2
0 2 . 9 6 7 3 . 0 0 1 0 D
2 4- Ma rc h- 2 0 04
13
Special Considerations
Configuring Main Controller Board
When performing maintenance or troubleshooting procedures on Series 2000
luminaires, it may be necessary to configure the Main Controller Board (MCB) for
installation. When moving an MCB from one luminaire another, different jumper
configurations must be set correctly in order for the luminaire to operate.
The Main Controller Board (MCB) contains two blue jumpers.
CAUTION: Always use anti-static precautions when working with PCBs.
Programming Jumper - J1 (For Vari-Lite engineering use.)
The jumper at J1 is necessary and must be in the correct position in order for the
luminaire to operate. Do not change the configuration of jumper J1 (
Figure 2-1: Jumper Locations on MCB
Luminaire Type Jumper - J11
The jumper at J11 configures the luminaire type between VL2000 spot, VL2000 wash
and VL2416 wash. For VL2000 spot or VL2416 wash luminaires, it is fitted to non-
active pins. (This inactive setting is the default or shipping configuration.) For
VL2000 wash luminaires, it is fitted to the active pins.
Power Supply Connection - J2
The power supply connection at J2 sets the luminaire type according to the power
supply output. (VL2416 wash luminaire - 1200W / VL2000 spot luminaire and
VL2000 wash luminaire - 700W). If the power selection setting and the luminaire type
setting jumper (J11) do not correspond, the luminaire will not operate properly.
Jumper at J1
Jumper at J11
Power Supply
Connection
at J2
Содержание VL2000
Страница 1: ......
Страница 18: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL xviii 24 March 2004 02 9673 0010 D...
Страница 62: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL 44 24 March 2004 02 9673 0010 D...
Страница 118: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL 100 24 March 2004 02 9673 0010 D...
Страница 172: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL 152 24 March 2004 02 9673 0010 D...
Страница 187: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL REFERENCE FOLD OUTS 02 9673 0010 D 24 March 2004 167 DMX Input Schematic...
Страница 188: ...VARI LITE VL2000 SPOT LUMINAIRE SERVICE MANUAL REFERENCE FOLD OUTS 02 9673 0010 D 24 March 2004 168 Ignitor Schematic...
Страница 189: ......