Technical data, Aura 2 

Height (cm) 

100 

Width (cm) 

50 

Depth (cm) 

45 

Weight (kg) 

104 

Output 

3-7 kW 

Nominal output 

5.0 KW 

Heated area 

30-105 m

2

 

Efficiency 

81% 

EEI 

108 

Flue gas data: 265°C at 25°C, 12 pa. 

Combustion chamber: (H x W x D):  
24.5-36.0x30.0x28.0 cm 
 
Smoke outlet Ø 15 cm  
Installation height, top: 97 cm  
Installation height, rear: 83 cm 
 
Distance to non-flammable material:  
5–10 cm (recommended) 
 
Distance to flammable material: 
Rear=12.5 cm, Side=30 cm, Front=30 cm 

 21 

 

 

 

 

 

 

 

How to correct a fault. 
 
Smoke entering room 
• 

Poor draught in the chimney. 

• 

Check that the flue and chimney are not blocked. 

• 

Check that the chimney height is correct in accordance with the surroundings. 

 
Glass and/or chimney soot: 
• 

Wood is too wet. 

• 

There is insufficient combustion air (secondary air). 

• 

You have closed the kindling air too quickly when you started the fire. 

• 

There must always be clear flames in the combustion chamber. 

 
The stove is not heating the room: 
• 

The wood is too wet (all the energy is being used up in drying the wood) or the wood is 

poor quality. 

• 

Check that the smoke guide plate is positioned correctly (free passage for smoke). 

• 

Insufficient combustion air (secondary air). 

 
The fire burns too intensely: 
• 

The gasket in the door or ash pan does not seal (it must be replaced). 

• 

The chimney draught is too powerful (fit a damper in the chimney). 

• 

Check that the kindling air is closed. 

 
The shaker grate is stuck: 
• 

Check that a piece of wood or similar is not stuck in the grate. 

• 

Check that the shaker grate bar is in the correct position. 

Recycling 

 

Packaging

 

In consideration of the environment, the packaging should be disposed of in accordance with 

local regulations for the disposal of waste. The packaging is 100% recyclable. 

 

Ceramic glass

 

Ceramic glass must be taken to the local recycling station and recycled with other ceramics 

and porcelain, where it is sent to a waste disposal facility. 

 

Vermiculite

 

Vermiculite panels from the stove must be taken to the recycling station, where they will be 

sent to a waste disposal facility

 

 

Содержание Aura 1

Страница 1: ...1 Varde Aura 1 Varde Aura 2 Varde Aura 3 Varde Aura 11 Varde Aura 3 Stone Installation and User Manual Revision 8 8th version 14 05 2018 UK Pottemagervej 1 7100 Vejle Denmark www vardeovne dk...

Страница 2: ...ldgaard CEO Varde Ovne A S 23 Warranty All Varde stoves undergo substantial quality control and we take pride in supplying the same high quality at all times We do however offer a 5 year warranty for...

Страница 3: ...7 cm Installation height rear 83 cm Distance to non flammable material 5 10 cm recommended Distance to flammable material Rear 12 5 cm Side 30 cm Front 80 cm Height cm 100 Width cm 51 Depth cm 45 Weig...

Страница 4: ...not heating the room The wood is too wet all the energy is being used up in drying the wood or the wood is poor quality Check that the smoke guide plate is positioned correctly free passage for smoke...

Страница 5: ...uding smoke guide plate Aura 1 and 11 100309 5703505042814 Aura 2 and 3 100318 5703505038831 Gasket for glass and ash pan product number and EAN number 100443 5703505045457 Gasket for door incl glue p...

Страница 6: ...ve contact the dealer who sold you the unit or contact your chimney inspector In particular following a long period of time where you have not used the stove before using it again you must make sure t...

Страница 7: ...What can you make a fire with This Varde stove has been approved and tested for the combustion of wood Only dry wood may be used with a max water content of 21 and a size that is suitable for the com...

Страница 8: ...me Varde Ovne A S Address Pottermagervej 1 7100 Vejle Denmark Fireplace Inspection Name RRF Address Im Lopperfeld 34b 46047 Oberhausen Germany Product Varde Product type Aura 1 11 2 3 and 3 Stone Type...

Страница 9: ...tioned next to it However we recommend that you keep a gap of 5 10 cm which will mean that you will be able to clean behind the stove If the chimney cleanout access door is behind the stove make sure...

Страница 10: ...door for the combustion air must be drawn to the right so that it is completely open for the combustion air When the fire is burning well remember to close the kindling air again since the stove and...

Страница 11: ...note that the damper must never be completely closed There must always be at least 20 cm of free passage through the chimney In some cases it can be an advantage on days when the wind is blowing stron...

Страница 12: ...onnect the stove using the rear outlet 13 How it works Fuel air damper or secondary air Turn the damper to the right to open the air Kindling air On ash pan closed Kindling air On ash pan Open Remembe...

Отзывы: