13
Vermiculite
The plates in the combustion chamber
are called
vermiculite plates
and will eventually
become worn, as will the smoke guide plate. Accidental breakage of a plate, for instance by
hitting it hard with a piece of wood, will not affect the quality of the combustion. You do not
need to replace the plate until the gap is approx. 5 mm wide.
Vermiculite
A special, non-flammable material that looks like chipboard. The plates act as insulation and at
the same time protect the stove against wear and tear. The vermiculite plates and the smoke
guide plate are not covered by the warranty.
Vermiculite is a
very porous
material and should be handled with care. When refilling the
stove, stoke the wood carefully and use a glove.
Only use original parts from Varde Ovne A/S
How too replace the Vermiculite
1.
Lift the smoke deflector plate slightly, tilt the rear end forward and remove.
2.
Lift the left side plate slightly and rotate outwards.
3.
Lift the right side plate and rotate outwards.
4.
Lift the rear plate up and out of the stove.
When fitting the new vermiculite plates, begin with the rear plate and repeat the steps in the
reverse order, finishing with step 1
2
1
4
Vermiculit set,
Item no.: 1801506 og 1802506
1.
Smoke guide plate
2.
Left side plate back
3.
Left side plate front
4.
Right Side Plate back
5.
Right Side Plate front
6.
Rear
6
3
5
Max height of firewood
Содержание Uniq
Страница 1: ...1 Installation and User guide Revision 6 Varde Uniq ...
Страница 19: ...19 ...
Страница 20: ...20 ...