background image

Adjust Air & Water Ratio (FIG 7) 

1. Adjust the air and water via the variable valves on the 

side of the unit to create the desired e

ect size and type.

2. Take into account any water accumulation on the 

surrounding areas. The 6b is designed to create a full 
plume of flame e

ect while maintaining a dry surrounding 

area thus creating an e

ect that is safe to use near other 

equipment. 

3. NOTE: If the Air supply is adjusted too low, the internal 

piston mechanism of the 6b’s nozzle will activate and both 
air and water output will be stopped.  To restore air and water output, increase air 
supply.

4. NOTE: Increasing the amount of air in relation to the amount of water will result in a 

narrower, thinner e

ect, and will result in less or no water collecting on the 

surrounding area.

5. NOTE: Increasing the amount of water in relation to the amount of air will result in a 

wider, thicker e

ect, but could cause water to collect on surrounding area.

6. NOTE: Due to di

erences in relative humidity the e

ect may need to be adjusted for 

more or less water.  

Nozzles (FIG 8) 

1. Nozzle tips may be changed to create di

erent e

ects. Use 12mm and 14mm 

wrenches to remove and replace nozzle tips.

2. It may be necessary to clear a blockage if the nozzle becomes clogged.  Use a 

14mm wrench to remove the nozzle tip, and inspect for debris.  

3. A plume that is wide and not particularly tall is a sign that debris has entered the 

nozzle and most likely collected on the inside of the tip.  Remove the tip to clean 
out debris.  

Storing the Unit 

Be sure to drain remaining water from the unit before storage. 

1. Briefly connect the air supply to the water in on the VF6b unit. This creates a 

bubble of air to clear the water line.

2. Disconnect the air supply from the unit and reconnect correctly.  Run the unit using 

ONLY the air channel. Leave the water channel at 0.  Run the unit until all of the 
water is cleared from the e

ect plume.  

Page   of 

9

12

Rev. 2.0 11/20

FIG. 7

Содержание VF6b

Страница 1: ...VF6b Manual Page of 1 12 Rev 2 0 11 20...

Страница 2: ...h 6b unit to the light source FIGS 1 2 7 Connect Power and Data to the 6b FIG 3 7 Set the DMX address FIG 4 8 Set Initial Air Water Ratio FIG 5 8 Connect air water supply FIG 6 8 Power the lighting fi...

Страница 3: ...dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch The VaporFlame 6b requires an input voltage of 100 240 VAC and has an internal auto switching power supply B...

Страница 4: ...ventilation DO NOT place objects directly in the main e ect plume as they may get wet The main plume is described as the part of the e ect closest to the nozzle tip where the water has yet to atomize...

Страница 5: ...Page of 5 12 Rev 2 0 11 20...

Страница 6: ...mounted at any angle No heat or flammable material makes the VaporFlame safe to use in close proximity to artists gear and scenic pieces The VF6b takes 2 channels of DMX for individual control of the...

Страница 7: ...he face of your lighting unit using appropriate screws FIG 2 2 Attach the VaporFlame chassis to the Mounting Adapter using pan head screws and safety nuts 3 NOTE VaporFlame Mounting Adapter will only...

Страница 8: ...6b 3 Firmly seat the connectors until they click and lock into place 4 Air supplied to the unit should be dry and free from air compressor condensation 5 NOTE Do not cross the streams Air and water s...

Страница 9: ...er thicker e ect but could cause water to collect on surrounding area 6 NOTE Due to di erences in relative humidity the e ect may need to be adjusted for more or less water Nozzles FIG 8 1 Nozzle tips...

Страница 10: ...ilding pressure as is supplied to a sink or faucet is fine Unpleasant odors can occur if water is left in the unit for extended periods of time IMMEDIATELY clean the unit if found odors are present We...

Страница 11: ...ship back to owner at VaporFlame s expense If VaporFlame determines the fixture is not under warranty VaporFlame will ship the fixture back to the owner at the owners expense If VaporFlame determines...

Страница 12: ...nd water hoses are correctly connected to an air and water supply 4 Pinch your fingers over the nozzle tip sealing the output of air and then release This can equalize internal pressure blockages 5 Re...

Отзывы: