Vantron LNG-PRN-0137 Скачать руководство пользователя страница 5

LNG-PRN-0137 User Manual (HW)

 

 

2

 

Technical Support and Assistance 

Should you have any question about the Product that is not covered in this manual, contact 
your sales representative for solution.   

US Office: Vantron Technology, Inc.   

Address: 440 Boulder Court, Suite 300 Pleasanton, CA 94566   

Tel: 916-202-7042   

Email: 

[email protected]

   

China Office: Chengdu Vantron Technology Co., Ltd. 

Address: 6th Floor, 1st Building, No.9, 3rd WuKe East Street, WuHou District, Chengdu, P.R. 

China 610045   

Tel: 86-28-8512-3930/3931, 8515-7572/6320   

Email: 

[email protected]

 

Regulatory Information 

The Product is designed to comply with: 

-

 

Part 15 of the FCC Rules; 

Please refer to 

Appendix 

for Regulatory Compliance Statements. 

Regulatory certification information is available on-device. 

Choose      Setting > System > Authentication information 

Symbology   

This  manual  uses  the  following  signs  to  prompt  users  to  pay  special  attention  to  relevant 
information. 

 

Caution for latent damage to system or harm to personnel   

 

Attention to important information or regulations 

 

 

 

Содержание LNG-PRN-0137

Страница 1: ...LNG PRN 0137 User Manual LNG PRN 0137 User Manual Product Version 1 1 Date Jan 4 2023 Copyright Chengdu Vantron Technology Co Ltd All rights reserved...

Страница 2: ...LNG PRN 0137 User Manual Document Information This table describes the version and release date No Version Author Date Description 1 1 0 Liu Huan 03 10 2022 First release 2 1 1 Liu Huan 04 01 2023...

Страница 3: ...2 1 6 SYMBOLOGY 2 1 7 GENERAL SAFETY INSTRUCTIONS 3 1 8 PRECAUTIONS FOR POWER CABLES AND ACCESSORIES 3 2 OVERVIEW 5 3 LNG PRN 0137 HARDWARE INSTRUCTIONS 6 3 1 PRODUCT APPEARANCE AND INTERFACES 6 3 2...

Страница 4: ...ual registered or not are properties of their respective owners Under no circumstances shall any part of this user manual be copied reproduced translated or sold This manual is not intended to be alte...

Страница 5: ...3rd WuKe East Street WuHou District Chengdu P R China 610045 Tel 86 28 8512 3930 3931 8515 7572 6320 Email sales vantrontech com cn Regulatory Information The Product is designed to comply with Part 1...

Страница 6: ...lace without risk of trips Cut off the power before inspection of the Product to avoid human injury or product damage Precautions for Power Cables and Accessories Use proper power source only The Prod...

Страница 7: ...will cause battery over heated distort smoke or burning N ins rez pas la batterie sur le chargeur pendant une longue p riode Si la charge au del du temps normal la batterie est toujours dans le charge...

Страница 8: ...linux system based on intel Pentium N4200 with a customer logo on the glass cover This medical tablet is IP64 rated and has a 10 inch LCD with a resolution of 1920 x 1200 to support standard touch con...

Страница 9: ...0137 Hardware Instructions LNG PRN 0137 is developed based on Intel Pentium N4200 series Product Appearance and Interfaces Figure 3 1 Figure 3 2 and Figure 3 3 show the top view bottom view and front...

Страница 10: ...LNG PRN 0137 User Manual HW 7 Figure 3 2 Bottom view...

Страница 11: ...LNG PRN 0137 User Manual HW 8 Figure 3 3 Front view...

Страница 12: ...d in Table 3 1 Table 3 1 Features Features Processor Intel Pentium N4200 Quad core 2 5GHz Max LPDDR4 2133MHz 8GB 1 x M 2 2280 SSD Slot 1 x SATA 1 x LVDS 1 x M 2 M KEY slot 1x M 2 E KEY 1 x Type C 1 x...

Страница 13: ...0 SSD Slot default 256GB Display Resolution Dual LVDS 1920 x 1200 30Hz Audio Audio 2 x Speaker Peripheral LAN 1 x 10 100 Ethernet Security 1 x TPM Button 1 x Standard power RTC Supported Software OS Y...

Страница 14: ...LNG PRN 0137 User Manual HW 11 Dimensions...

Страница 15: ...iption is based on the connector sketch map Necessary information such as pictures are attached Type C connector Pin Name Type Description A1 GND P GND A2 SSTX1_P P NC A3 SSTX1_N P NC A4 VBUS_1 P POWE...

Страница 16: ...B7 DM2 P NC B8 SBU2 P NC B9 VBUS_4 P POWER 20V B10 SSRX1_N P NC B11 SSRX1_P P NC B12 GND4 P GND POGO pin definition Table 4 1 and Table 4 2 describe the valid signal of connector on the LNG PRN 0137...

Страница 17: ...s a Power preparation Please confirm the power input is 20V and the current is 2 25A as recommended b Our adapter is applicable to this device only Do not insert any third party equipment We do not as...

Страница 18: ...e that the abandoned batteries are disposed of according to local regulations on waste disposal Do not throw batteries into fire or put in common waste canister as they are explosive Products or produ...

Страница 19: ...de this service as long as the components are available in the market and the CUSTOMER is requested to place a purchase order up front Parts repaired will have an extended warranty of 3 months Returne...

Страница 20: ...r is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connec...

Страница 21: ...nce to co channel mobile satellite systems RF exposure information and statement This equipment complies with IC RSS 102 radiation exposure limits set forth for an uncontrolled environment The guideli...

Страница 22: ...trices sont fond es sur des normes qui ont t labor es par des organisations scientifiques ind pendantes au moyen d une valuation p riodique et approfondie des tudes scientifiques Les normes comprennen...

Отзывы: