126360-01

Rev. A

07/12

WARRANTY

KEEP THIS WARRANTY

FMI PRODUCTS, LLC LIMITED WARRANTIES

New Products

Standard Warranty:

 FMI PRODUCTS, LLC warrants this new product and any parts thereof to be free from defects 

in material and workmanship for a period of four (4) years from the date of first purchase from an authorized dealer 

provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s 

warnings and instructions.
For products purchased for commercial, industrial or rental usage, this warranty is limited to 90 days from the date 

of first purchase.

Factory Reconditioned Products

Limited Warranty:

 FMI PRODUCTS, LLC warrants factory reconditioned products and any parts thereof to be 

free from defects in material and workmanship for 30 days from the date of first purchase from an authorized dealer 

provided the product has been installed, maintained and operated in accordance with FMI PRODUCTS, LLC’s 

warnings and instructions.

Terms Common to All Warranties

The following terms apply to all of the above warranties:
Always specify model number and serial number when contacting the manufacturer. To make a claim under this 

warranty the bill of sale or other proof of purchase must be presented.
This warranty is extended only to the original retail purchaser when purchased from an authorized dealer, and only 

when installed by a qualified installer in accordance with all local codes and instructions furnished with this product.
This warranty covers the cost of part(s) required to restore this product to proper operating condition and an allow

-

ance for labor when provided by a FMI PRODUCTS, LLC Authorized Service Center or a provider approved by 

FMI PRODUCTS, LLC. Warranty parts must be obtained through authorized dealers of this product and/or FMI 

PRODUCTS, LLC who will provide original factory replacement parts. Failure to use original factory replacement 

parts voids this warranty.
Travel, handling, transportation, diagnostic, material, labor and incidental costs associated with warranty repairs, 

unless expressly covered by this warranty, are not reimbursable under this warranty and are the responsibility of 

the owner.
Excluded from this warranty are products or parts that fail or become damaged due to misuse, accidents, improper 

installation, lack of proper maintenance, tampering, or alteration(s).
This is FMI PRODUCTS, LLC’s exclusive warranty, and to the full extent allowed by law; this express warranty 

excludes any and all other warranties, express or implied, written or verbal and limits the duration of any and all 

implied warranties, including warranties of merchantability and fitness for a particular purpose to four (4) years on 

new products and 30 days on factory reconditioned products from the date of first purchase. FMI PRODUCTS, LLC 

makes no other warranties regarding this product.
FMI PRODUCTS, LLC’s liability is limited to the purchase price of the product, and FMI PRODUCTS, LLC shall not 

be liable for any other damages whatsoever under any circumstances including indirect, incidental, or consequential 

damages.

Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental 

or consequential damages, so the above limitation or exclusion may not apply to you. 
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 
For information about this warranty contact:

Model (

located on product or identification tag

) _____________________________

Serial No. (

located on product or identification tag

) __________________________

Date Purchased  __________________________

Keep receipt for warranty verification.

2701 S. Harbor Blvd.

Santa Ana, CA 92704

1-866-328-4537

www.fmiproducts.com

Содержание VFS32NRK

Страница 1: ...elycallyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali...

Страница 2: ...es air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manu...

Страница 3: ...r flame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandaway...

Страница 4: ...en Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air i...

Страница 5: ...ews Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging ap...

Страница 6: ...stall fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height ________...

Страница 7: ...e additional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila...

Страница 8: ...r Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings...

Страница 9: ...e receptacle included with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth...

Страница 10: ...page 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace...

Страница 11: ...15 INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in encl...

Страница 12: ...facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover an...

Страница 13: ...r sleet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volum...

Страница 14: ...roperly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Tank Vent Pointing Down CONNECTING FIREPLACE TO GAS S...

Страница 15: ...flexible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS...

Страница 16: ...or Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipme...

Страница 17: ...ck side of this log needs to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit...

Страница 18: ...sections of chassis assembly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the reces...

Страница 19: ...g the ember chunk in place when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and...

Страница 20: ...Chunk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen br...

Страница 21: ...the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in pla...

Страница 22: ...tact a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON po...

Страница 23: ...r fireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fin...

Страница 24: ...tydamage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of du...

Страница 25: ...en in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubi...

Страница 26: ...intenance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt an...

Страница 27: ...cts 1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If fo...

Страница 28: ...ntenance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all...

Страница 29: ...ng Weight 122 lbs For input adjustment REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty Contact authorized dealers...

Страница 30: ...26360 01A 30 PARTS LOG BASE ASSEMBLY MODELS VFS32NRK VFS32PRK VFS36NRK AND VFS36PRK See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 19...

Страница 31: ...103781 02 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465...

Страница 32: ...dle 1 101004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 D...

Страница 33: ...23 01 Panel Closure Smooth 2 106651 01 Panel Closure Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer To...

Страница 34: ...1 06 125852 06 Log Left Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 12...

Страница 35: ...finished mantel or wall open ing edges etc NOTICE All accessories may not be available for all fireplace models Purchase these fireplace accessories from your local dealer If they can not supply these...

Страница 36: ...s product and or FMI PRODUCTS LLC who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic ma...