2

 

Service Switch 

An off switch is provided to disconnect power between the 
Station and the fixture for lamp replacement. Service other 
than lamp replacement requires the breaker to be switched off. 
 

Default Mode 

The RF Dimmer Station has a default mode that operates 
without programming or being connected to the Vantage 
System. If a Dimmer has been programmed but 
communication with the controller is lost the Dimmer will revert 
to default operation. Multiple gang Dimmers loads are 
numbered from left to right. 
 

Station Type 

Button to Load Mapping 

1-gang Dimmer 

All buttons control the one 

load.  

All buttons in first (left) gang. 

One column of buttons 

The top button controls 

first load.  

Second button controls 

second load etc. 

All buttons in first gang. 

Two columns of buttons.  

Top left button controls 

first load.  

Top right button controls 

second load. 

Second row left button 

controls third load. 

Second row right button 

controls fourth load. 

One or two buttons 

per gang. 

Each button(s) controls the 

load in its gang. 

 
When default is the desired operation for a button, it can be left 
unprogrammed and will continue to operate in default mode 
even if other buttons on the dimmer are programmed.  
 
When power is restored from a power outage the Dimmer will 
return the loads to the last load level. This will occur whether 
or not the Dimmer is connected to a system. 
 

Default Operation 

Button 

Action 

Load Operation 

Single 

Press 

The load toggles between off and the learned 

level. The turn on ramp time is 1.5 seconds 

and the turn off fade time is 5 seconds. 

Double 

Press 

The load ramps to 100% in 1.5 seconds. The 

second press must be within 1 second of the 

first press. 

Press and 

Hold 

After a one second delay the load will ramp in 

the opposite direction from the last press and 

hold. If the load reaches 0 or 100% it will 

reverse direction. When the button is released 
the current load level will be saved as the new 

learned level for that button. The cycle time is 

5 seconds from 0-100%. 

 
When multiple buttons control the same load, each button will 
have its own learn level.  
 

Default IR Mode 

If the Dimmer has the optional IR receiver, the Dimmer will 
have a default IR mode that is active when the RF Dimmer 
Station is not communicating with a system or when none of 
the Scene Codes in its IR Zone have been programmed. 
  
The Scene Codes 230-239 are transmitted by the Scene 
buttons 1-10 on the Vantage IR Remote Control. 
 

The Scene buttons 1-4, codes 230-233, controls loads 1-4 
operating the same as the default operation for a button. 
Scene 9, code 238, will turn all station dimmer loads on. Scene 
10, code 239, will turn all station dimmer loads off. 
 
Unlike the buttons, if any IR Scene button is programmed all of 
the IR Scene buttons stop executing default operation. 
 

Reset

  

The Dimmer stores the configuration data locally so that it will 
continue to operate correctly if communication with the system 
is lost. This information includes: LED properties, sounder 
properties, load profile, last load level, and default learn levels. 
 
To reset this information to the factory default, press and hold 
switches 1-3 when power is applied to the station. The board 
will respond by sounding three slow beeps to indicate that the 
reset took place. Since buttons do not need to be installed in 
switches 1-3, the faceplate may need to be removed so that 
the switch matrix can be pressed directly. 
 
After a reset the load profile will be Default, the learn levels will 
be 50%, the loads will all be off, and other settings will be at 
factory default. 
 

Diagnostic Information 

If the faceplate is removed the Status LED can be seen in the 
approximate middle of the station’s switch matrix. The Status 
LED blinks evenly or flashes 2, 3, 4 or 5 times followed by a 
pause to indicate status information. 

Off

: The station is not powered. A line voltage connection has 

not been made or the line feed breaker is off. 

Even blink:

 Station is operating correctly and is configured. 

Two blinks:

 Station is operating correctly but is not 

configured. 

Three blinks:

 Station is not communicating with the Master 

Controller. Verify that station bus wiring conforms to Vantage 
guidelines.  

Four blinks: 

Dimmer problem.  Please contact the factory. 

Five blinks

: Configuration mode.  

 

 

 

 

FCC ID:  PII-RDS1000
This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following two conditions:  (1) This device may not cause 
harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 
 
NOTE: This equipment has been tested and found to comply with the 
limits for a Class B digital device, pursuant to Part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This 
equipment generates, uses and can radiate radio frequency energy and, 
if not installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installation. If 
this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or 
more of the following measures: 
-- Reorient or relocate the receiving antenna. 
-- Increase the separation between the equipment and receiver. 
-- Connect the equipment into an outlet on a circuit different 

from that    

to which the receiver is connected. 
-

Consult the dealer or an experienced radio/TV technician for 

help. 

 
Changes or modifications to this product not expressly approved by 
Vantage Controls could void the user’s authority to operate this 
product.

 