DIN InFusion Controller II — MODEL:  IC-DIN-II 

page 1 of 7 

I N S T A L L A T I O N 

 

V A N T A G E C O N T R O L S . C O M  

V A N T A G E   I N S T A L L   G U I D E S

 

2168 West Grove Parkway, Suite 300, Pleasant Grove, UT.  84062   USA 
Telephone:  801 229-2800 

 Fax:  801 224-0355 

DIN InFusion Controller II — MODEL:  IC-DIN-II

 

 

Overview 
The InFusion™ IC-DIN-II is Vantage’s most 
powerful automation controller to date, 
featuring a new, extremely fast processor 
improving processing performance. 
Systems using the previous InFusion DIN 
controller may be upgraded by simply 
installing the new controller,* converting 
the project file in Design Center 3.3 or higher, and downloading to 
the new controller.  
 
* See 

Replacing and/or Upgrading InFusion Controllers

 for 

additional information. 
 
Features 

 

The InFusion Controller is the main “CPU” of Vantage’s 
complete systems integration solution

 

 

Automatic crossover support, RJ45 Ethernet connection.

 

 

Secure access – password protected

 

 

Design Center connection through local network or offsite

 

o

 

Firmware updates and full or minor program changes

 

 

Automatically restores previous firmware and 
program code if update fails

 

o

 

Diagnostics

 

o

 

Read system

 

o

 

Project control

 

 

Built-in Ethernet jack

 

 

Type-A, USB port (future features ready)

 

o

 

The USB port is not used on IC-DIN-II controllers to 
program from Design Center as in previous InFusion 
controller models

 

 

Micro SD

 card support (included)

 

 

Automatic System Backups to 

micro SD

 card

 

o

 

Manually through front panel – real time

 

o

 

Within 24 hours of programming system

 

-

then

o

 

Weekly

 

o

 

Up to 52 backups total

 

o

 

Oldest backup is replaced when 52 limit is reached

 

o

 

Backups may be used to program system controllers 

 

 

Restore entire system from System Backups

 

o

 

Undo option from last Restore

 

 

Ram and Flash memory

 

 

One controller supports up to 120 WireLink™ stations and up to 
120 RadioLink™ stations

 

 

Local LCD interface provides limited control, status and 
diagnostics

 

 

Lithium battery retains time and system status in a power 
outage

 

 

Maintains real and astronomical time clocks

 

 

Design Center software is used to program the Controller

 

 

The Controller runs independent of a PC after initial setup and 
programming

 

 

Application code is upgradeable through Design Center 
software

 

 

InFusion Controllers operate as stand-alone or networked

 

 

Five RS-232 Ports

 

 

Two RS-485 Ports (shared with SE buses 3 and 4; simultaneous 
RS-485 and SE bus connections are not possible)

 

 

Manual Override Switch

 

 

Reset Switch

 

 

Built-in Protection, electronic isolation between controllers

 

 

*The Vantage InFusion Controller Network can have up to 
thirty-one Controllers when connected via Ethernet 

 

*15 Controllers maximum on each Controller to Controller 
Bus run.  
 

InFusion Controller Specifications 

Description

 

Specification

 

Dimensions HWD 

85.7mm x 157.2mm x 61.9mm

3.38” x 6.19” x 2.44” 

Weight 

417 g / 0.92 lb. 

Mounting 

35 mm DIN Rail (EN 50 022: 1977)

Power Requirement 

36VDC/3.6A or 24VDC/2.5A

Description

Specification

Power Supplies 

 

PSU36-DIN

 – 130W, 36VDC 

 

ACPDXXSM2 – 

60W, 24VDC 

 

DIN POWER-MC – 96W, 24VDC, Europe 

Lightning / Surge 

Protection Static Shock 

IO. All ports/case 

IEC 61000-4-2  

Low Voltage, ITU-T K.20 

Bus Network

Max. Length of 

Combined

 

IC-II to IC-II  

2000ft / 609m- using 16-18AWG

/ 1.31-0.75mm

2

, 2-conductor, twisted pair, 

non-shielded wire 

C2C, IC Network

Ethernet (see 

Screen 16

, p. 3)

Station Bus Specification 

2C, 16AWG / 1.31mm2, twisted, non-shielded, 
<30pF per foot. Separate a minimum of 12" / 

30.5cm from other parallel communication 

and/or high voltage runs. 

Station Bus Power 

Supply, IC-36-1 

Each

 station bus run has a 60W power supply;

 

Station Bus Run 1 = 60W 

 

Station Bus Run 2 = 60W 

Station Bus Power 

Supply, IC-24-1 

Shared

, 35W max. power supply 

combined

to 

both station bus runs. 

Max. Wire Length Station 

Bus 

609m / 2,000ft of cabling max. on each 

station bus. No station more than 305m / 

1,000ft from Controller. 

Wire Configuration of 

Station Bus 

Daisy Chain, Branch, Star

(contact support for  

Station Bus Best Practices

Max. # WireLink Stations 

IC-36V 

Up to 60 Stations each bus or until the 60W 

supply per bus is used 

Max. # WireLink Stations 

IC-24V 

Up to 50 Stations each bus 

or

until the 

shared

 35W supply is used 

Cooling

Convection

Lithium Battery Backup 

Disk battery CR2032, 3Volt

2.5 yrs. un-powered or 20 yrs. powered (field 

replaceable – see 

Caution

 at end) 

Ambient Operating 

Temperature 

0-40°C / 32-104°F 

Ambient Operating 

Humidity 

5-95% non-condensing 

UL/cUL/CE/FCC Certified

YES

 
Software/Firmware/Installation Requirements 
Installation of Vantage products should be performed or 
supervised by a

 Certified Vantage Installer. 

Design Center 

Software, version 3.3.X.X or higher must be used to program 
controller models with the “-II”. Using IC-1 and IC-II controller 
models on the same system, is not supported. 

Disconnect power 

when plugging in or un-plugging the controller’s power connector. 

 
Use a dedicated breaker to power the controller. Multiple InFusion 
Controllers may share the same breaker when in close proximity. 
 
Powering the DIN Controller 
The DIN Controller must be wired to Vantage’s 

PSU36-DIN

 130W, 

36VDC or 

ACPDXXSM2 

60W, 24VDC power supply. Power 

supplies must be mounted to 35mm DIN rail in any standard DIN 
Enclosure compatible with the maximum power dissipated. Before 
using pull out the lithium battery tab insulator on the DIN 
Controller. Connect the positive (+) output of the power supply to 
the 24V/36V screw terminal and the negative side to one of the 
ground terminals. The Controller and Power Supply must be earth 
grounded. Carefully follow the 

Wiring Diagrams

 below. 

DO NOT 

USE ANY OTHER POWER SUPPLY

*

 
*NOTE:  Another (

Vantage Certified

) 96W, 24VDC power supply, 

DIN POWER-MC, is also available in the European region from 
Vantage EMEA; visit, 

www.vantage-emea.com

 
NOTE: 

The

 earth ground on the DIN Controller and power supply 

should be the 

ONLY

 earth ground connection in 

this

 DIN 

Controller’s immediate system. Controller Bus (connections 
between controllers) connections are isolated so a new earth 
ground reference for each Controller is normal.  

 

Vantage recommends a 

minimum

 0.75mm

2

 / 18AWG wire, 

stranded, between the power supply and the controller. 

 

Recommended:  keep wires no longer than 1 meter between 
the power supply and the controller. 

Содержание InFusion IC-DIN-II

Страница 1: ...30W 36VDC ACPDXXSM2 60W 24VDC DIN POWER MC 96W 24VDC Europe Lightning Surge Protection Static Shock IO All ports case IEC 61000 4 2 Low Voltage ITU T K 20 Bus Network Max Length of Combined IC II to I...

Страница 2: ...e controller by connecting the computer directly to the controller via an Ethernet cable standard or cross over type Set the controller IP address to the Default setting 192 168 0 controller number Se...

Страница 3: ...hen release Press RESET by itself to exit service mode Service Mode Screen should appear similar SCREEN 4 IP SETTINGS A static IP address may be assigned to the IC Once a static IP address has been as...

Страница 4: ...I N S T A L L A T I O N Vantage 8 17 2016 IS 0600 B DIN InFusion Controller II MODEL IC DIN II page 4 of 7...

Страница 5: ...e Security Level is set to None and no Users and Devices exist If the security level is changed to Local or Remote at least one Admin user must be added before exiting the dialog box 4 To create a use...

Страница 6: ...ed to connect Design Center contains the system s SD card Recommendation Install one SD card per system Backup and Restore From Design Center 1 In Design Center click on System Backup And Restore and...

Страница 7: ...oller Power Supply_PSU36 DIN_ACPDXXSM2_install_IS 0491 DIN_Electronic Load Dimmer Station_ELDS4 1 DIN_install_IS 0484 DIN_InFusion Controller II_IC DIN II_install_IS 0600 DIN_Lite Controller DIN_insta...

Отзывы: