SECTION TWO - Setup & Testing
CC-STAT
©Vantage, 41184 / IS-1308191-A
page 16 of 23
System Test Menu
The system test menu is used to test a system after installation. The outputs of the thermostat or
humidistat can be manually activated to test their function. The instructions below show how to
enter the test mode and turn outputs on and off.
HOW TO ENTER THE SYSTEM TEST MENU:
Press [MODE] to set system to off.
Press and hold [FAN] and [MODE] for three
seconds to enter system test mode. Note:
Buttons will not be shown in humidistat
mode. Press in the same area that the button
would be displayed.
The screen of the first test step is displayed:
Test Number
Thermostat System Test
60
Heating equipment test
61 Cooling
equipment
test
62
Auxiliary equipment test (HP only)
63
Fan equipment test
Test Number
Humidistat System Test
70
Humidification equipment test
71
Dehumidification equipment test
The test number is displayed on the upper
left, and the output state is displayed in the
message center.
Press
to turn on the output (01). For multi
stage output, press
again to turn on the
2
nd
stage (02).
Press
to turn off all the outputs (00).
Press [BACK] or [NEXT] to change to the
next test step.
When the last step is done, press [NEXT].
The message “installer test complete“ will
display.
All minimum on and off timers will be reset
after returning from system test mode.
Note: Second stage will only be displayed
when the thermostat is set to multi-stage
mode.