Vansco VMM1615 Скачать руководство пользователя страница 18

VMM1615 

 

 

Quick Start

 

 

Data Link Adapter (DLA) kit (comes with cables needed for connecting the 
DLA to your PC and to the rest of the system) 

 

desktop power supply compatible with the VMM1615 and controller I/O 
board loads (a 12 V DC, 3 A fixed voltage supply is generally suitable, unless 
driving more significant loads) 

 

procurement drawing for the version of VMM1615 you are using, indicating 
the configuration options for your variant of the product. 

 

software tools and files required for programming and downloading software 
for the VMM1615. 

 

Note: 

With the exception of the PC and desktop power supply, all materials 

and software are available from Parker Vansco. Please consult your Parker 
Vansco Account Representative for specific details and pricing information. 

 

2.2.  Install the Required Software Tools 

Before using the VMM1615, install the following software tools onto your PC: 

 

Data Link Adaptor (DLA) drivers  

 

The DLA acts as the interface between the PC and the VMM1615. Before 
using the DLA, you must install the DLA drivers. 

 

Parker Vansco Software Tools 

 

Parker Vansco provides the VMMS software tool to create and download 
software for the VMM1615. Contact your Parker Vansco Account 
Representative, or visit the Parker website to get further information on 
how obtain a product key. 

 

2.2.1.  Install the Data Link Adaptor Driver Software 

A Data Link Adaptor (DLA) is needed when connecting the VMM1615 in a 
development system. 

Note:

 Parker Vansco provides the latest DLA software releases through its 

web site. Please contact your Parker Vansco Account Representative for 
details on how to download the latest DLA driver software. 

The Parker Vansco DLA requires the installation of drivers on your PC. To install 
the Parker Vansco DLA drivers: 
1.

 

Download the driver, run the extracted file, and follow the Install Wizard. Do 
not connect the USB DLA until the driver installation is completed. 

2.

 

Connect the USB DLA to a USB port on your PC. The Found New Hardware 
screen opens. 

 

Содержание VMM1615

Страница 1: ...Vansco Multiplexing Module VMM1615 User Guide HY33 5008 IB US UG VMM1615 154200 201309 003...

Страница 2: ...is and testing is solely responsible for making the final selection of the system and components and assuring that all performance endurance maintenance safety and warning requirements of the applicat...

Страница 3: ...2 1 Install the Data Link Adaptor Driver Software 6 2 3 Connect the VMM1615 to a Development System 7 2 3 1 Power Up the Development System 8 2 4 Create and Download Ladder Logic Applications 9 3 Conn...

Страница 4: ...ion Connection 47 6 3 Solid State Relays 49 6 3 1 Solid State Relay Capabilities 49 6 3 2 Solid State Relay Installation Connections 50 6 3 3 Solid State Relay Diagnostics 52 7 Communication 53 7 1 Co...

Страница 5: ...User Guide v Contents 10 6 1 Open Collector 72 10 6 2 Connecting a Switch to the VMM1615 73 10 6 3 Voltage 73 10 6 4 Potentiometer Ratiometric 74 11 Startup 77 12 Glossary 79 13 Index 85...

Страница 6: ......

Страница 7: ...e course of its publication history Release Date Description of Change Rev 003 September 2013 Update to match Product Specification ver 02A Minor editorial changes throughout Rev 002 September 2012 Br...

Страница 8: ......

Страница 9: ...quipment or degradation of signal When you see these symbols follow the instructions carefully and proceed with caution General safety regulations Work on the hydraulics control electronics may only b...

Страница 10: ...system 1 Disconnect the electrical connections between the system and external equipment 2 Disconnect the negative cable from the battery 3 Disconnect the positive cable from the battery 4 Connect th...

Страница 11: ...verified Do not start the machine if anyone is near the machine Safety during maintenance and fault diagnosis Before performing any work on the hydraulics control electronics ensure that The machine c...

Страница 12: ......

Страница 13: ...s than 32V This module is 100 compatible with other Vansco Multiplexing Modules Figure 1 VMM1615 The VMM1615 has 16 inputs and 15 outputs Inputs include programmable gain analog programmable attenuati...

Страница 14: ...ting the CAN 2 0B standard The standard protocol supported is SAE J1939 but others could be supported through custom software development The VMM1615 follows the controller module road map which provi...

Страница 15: ...s The following symbols are used in the schematic diagrams in this document Symbol Meaning General input General output Frequency input Analog input Frequency sensor Pulse sensor Resistive sensor Gene...

Страница 16: ...4 VMM1615 About the VMM1615 Symbol Meaning Pull up resistor Battery Fuse Resistor Ground Chassis ground...

Страница 17: ...ials 2 Install the required software tools provided by Parker Vansco 3 Connect the VMM1615 to a development system desktop and power it up 4 Download the ladder logic application software 2 1 Gather R...

Страница 18: ...Link Adaptor DLA drivers The DLA acts as the interface between the PC and the VMM1615 Before using the DLA you must install the DLA drivers Parker Vansco Software Tools Parker Vansco provides the VMMS...

Страница 19: ...ard power source and DLA to verify your ladder logic application The development system is an ideal environment for creating and downloading ladder logic software applications The following shows how...

Страница 20: ...that all controller I O board digital inputs jumpers and dip switches are properly configured for your module type Refer to the Controller I O Board Reference Manual for further details 2 Ensure that...