VANQ VQ-GLCP Series Скачать руководство пользователя страница 3

Shenzhen VANQ Technology Co., Ltd

.

VQ-GLCP Series THCMax Bloom Light

3

VQ-GLCP Series

THCMax Bloom light

1

Lamp Introduction

1.1

Brief Introduction

Thank you for purchasing VQ-GLCP series lamps. VQ-GLCP series lamps are specially designed for

horticultural auxiliary lighting, in conjunction with VANQ other series grow lighting , aiming to increase THC
content of industrial hemp flowers for indoor planting.

This manual not only introduces the purpose and parameters of lamps, but also introduces the installation

methods of lamps. Please read this manual carefully before installing the lamps and time switch. If you have
any questions, please feel free to contact us.

1.2

Lamp functions and characteristics.

1、

Improving photosynthetic efficiency,shortening the flowering cycle;

2、

Improving crop quality,increasing THC content,estimated yield up by 20-25%;

3、

Reduce fungi,molds and plant pests and maintain a healthy growing environment;

4、

Useful for the formation of plant, flowering, fruit coloring and vitamin C;

5、

Full range of models, UV only and UV+Far-red different models for customer choices

;

6、

Optimized optical design, together with main light source use, the even illumination distribution, make

sure high consistency of plant flower growth

;

7、

Far-red and UV circuits are designed separately, in combination with THCMax bloom lamp timing switch

(two channels and 16 timers) to meet the lighting needs of crops from growth to flowering.

2

THCMax Bloom light information and Specification

2.1

Basic Information

Item name

THCMax Bloom light

Manufacturer

ShenZhen VANQ Technology Co.,Ltd

Waterproof rate

Non-waterproof

Size

445Lx 472Wx42H(mm)

Working Temperature -20°C ~ 40°C | -4°F ~ 104°F
Beam angel

120°

Dimmable function

No

Warranty

1 Year

In order to simplify the content, in some chapters, THCMax bloom light are abbreviated as lamps.

Содержание VQ-GLCP Series

Страница 1: ...LCP Series THCMax Bloom Light Manufacturer Shenzhen VANQ Technology Co Ltd Address 3 BLDG B Debaoli lndustrial park NO 312 Jihua Road Longgang Shenzhen China Telephone 86 755 29042099 Fax 29042092 Ema...

Страница 2: ...D SPECIFICATION 3 3 THCMAX BLOOM LIGHT TIME SWITCH INTRODUCTION 5 4 SIZE AND PACKAGE 6 5 LAMP CONNECTION PRINCIPLE 8 6 PRECAUTIONS 9 7 INSTALLATION 10 8 OPERATION GUIDES TO TIME SWITCH OF THCMAX BLOOM...

Страница 3: ...THC content estimated yield up by 20 25 3 Reduce fungi molds and plant pests and maintain a healthy growing environment 4 Useful for the formation of plant flowering fruit coloring and vitamin C 5 Ful...

Страница 4: ...m Net Weight 1 6kg Features IR and UV light Manual attention Can not be used alone to be connected with the time switch of THCMax Bloom light installed onto the main lamps for application Model VQ GLC...

Страница 5: ...l VQ GLCP DTS8A Input voltage 85 265VAC 50 60HZ Timer function two channels timer separately each channel has 16 independent timers Size 193L 118W 98H mm Net weight 850g Switch capacity Single channel...

Страница 6: ...ly packaged 4 1 Lamp 1 Lamp size 2 Package ways Note Inner Packing A can be shipped directly as standard packing L 445mm W 472mm H 42mm W1 66mm L1 440mm Inner packing of lamp A 1pcs box Gross weight 2...

Страница 7: ...Item Name Specification QTY A M3 Screws PWM M3 6 round head cross screwed with medium thread 8 B ST4 0Screws PA ST4 8 Self tapping screws with round head and cross point tail 4 C Mounting bracket Siz...

Страница 8: ...e customers determine the way of connection and installation of lamps choose the number of THCMax Bloom light time switch 5 1 Connected Principle Diagram 1 THCMax bloom light and time switch are conne...

Страница 9: ...e read the following items carefully before you install the product 6 1 Installation precautions 1 Only certified professionals are able to install the lights 2 Make sure the power is switched off bef...

Страница 10: ...r flammable and explosive objects 5 Do not use lights and time switches outdoors 6 Do not use lights and time switches in environment with water lights and time switches are not waterproof 7 Installat...

Страница 11: ...ries THCMax Bloom Light 11 2 Fix the bloom lights Fix the M3 c screws on the slots of mounting bracket and lock it to the nuts of groove on the back of THCMax bloom light and then the THCMax bloom lig...

Страница 12: ...n t exceed 2 meters 4 Cords connection Connect the waterproof connectors of time switch and bloom light and connect the waterproof connectors of bloom light and VQ GLMX series lights finally tighten t...

Страница 13: ...LMX series lights Each time switch can connect to max 20 units VQ GLMX series lights The distance of Time switch and main VQ GLMX series light can t exceed 2 meters The distance of VQ GLMX series ligh...

Страница 14: ...ht 14 1 Install the THCMax bloom light 2 Disassemble the power supply from MG Octopus640 800 3 Put the Bloom light on the middle of the MG Octopus640 800 and fix it tightly by screws 4 Re assemble the...

Страница 15: ...connectors of bloom light and MG Octopus640 800 lights finally tighten the threaded cap The waterproof cords should be connected above the MG Octopus640 800 lights avoiding to block the lights especia...

Страница 16: ...disappears the time switch is unlocked 2 Lock short press the Cancel key four times or no operation in 30 seconds the time switch will recover to lock status there is a icon displayed on the left bott...

Страница 17: ...Press ON Auto OFF Key Press multiple times to switch working modes Auto Timer Enabled ON Timers Disable With Lamps ON or Timers Disabled With Lamps OFF Note 5 Note Note 1 During the operation of the...

Страница 18: ...ll setting are correct If not correct please repeat 1 3 5 Follow procedure Finish Timers Setting Back to Start up Scree 6 Follow procedure Make sue the switch under AUTO mode Example 2 THCMax Bloom Li...

Страница 19: ...Shenzhen VANQ Technology Co Ltd VQ GLCP Series THCMax Bloom Light 19 8 4 Time Switch Internal Circuit 9 THC Max Bloom Light UVB band light radiation distribution test Unit W cm...

Страница 20: ...itch and gently wipe with a dry duster 10 2 Storage Disposal 1 Store in a dry and clean environment the ambient temperature is 20 75 C 2 Products can not be disposed as unsorted municipal waste must b...

Отзывы: