VANNER
Incorporated
OWNER’S MANUAL
Vanner High Voltage Distribution Module OWNER’S MANUAL
10
Wiring Input/Output Specifications Cont'd
Positive Terminals and Fuse Terminals
The positive and fuse terminals are M8 x 1.25 studs
Tighten to a torque value of 100 lb-in (11 Nm)
Negative Terminals
The negative terminals are M10 x 1.5 studs
Tighten to a torque value of 150 lb-in (17 Nm)
Chassis Ground Terminal
The ground terminal is an M8 x 1.25 stud
Tighten to a torque value of 100 lb-in (11 Nm)
-
-
+
+
-
Channel 1
Output
+ and -
Channel 2
Output
+ and -
HV Input
+ and -
HVIL Switch
Channel 2
Fuse
Channel 1
Fuse
+
Note:
HVIL
switch and
connector are
mounted to this
surface on IAP
I
models.
Pre-charge
Relay
Board