3
ENGLISH
GB
afterwards mount the cover of the electrical connection (top left).
Outdoor work:
10. Fasten outside with polyurethane foam or mortar.
11. Shorten the motor supply cable and protective sleeve as needed.
12. Screw the external base plate [10] onto the outer facade, lead the engine supply cable through the base
plate and connect to the connection block outside according to the circuit diagram.
13. Lock and tighten the outside cover onto the external base plate, reattach the outer grille [11].
The work is to be carried out with the power supply switched off.
Remote control functions:
Switch to smaller ventilation level 40/25/15 m³/h
Switch to larger ventilation level 15/25/40 m³/h
ON/OFF switch (to lock the appliance airtight, the locking lever must also be
shifted to the right on the panel)
During operation in summer the interval switching is suspended so that the
aeration/cooling of the rooms at NIGHT is supported.
Commissioning of an appliance (G1):
1. Connect the power supply professionally after installing the heat recovery unit (remove front cover).
2. Briefly press the control button [E] [13]. Afterwards, the control system switches to recording mode and
confirms with
2 short blinking signals of the LED.
3. Now press any key of the radio remote control.
4. The LED briefly lights up as confirmation, now the radio remote control is ready for use.
5. Close the front cover.
6. Turn the lever of the locking cover [F] on the inside to the right to "ON".
7. Switch on the appliance with the radio remote control. (central key)
Commissioning of one or more appliance pairs (G1 + G2) and (G3 + G4):
1. Commission the first appliance (G1) as described.
2. Shut off and disconnect the second appliance (G2) from the mains!
3. Remove the front cover of the second appliance (G2) and remove the cover of the control unit
(bottom left) [14].
4. Turn the switch [G] to the left to the "ON" position [15].
5. Reassemble the control unit's shrouding again.
L
N
L
N
Inside connection
Outside connection
Red (+)
Black (-)
Blue PWM
Yellow FG
Red (+)
Black (-)
Blue PWM
Yellow FG
Inside
24 V =
230 V
~50 Hz